Vascular and endovascular surgery · 2011
Successful extra-anatomical recanalization of occluded superficial femoral arteries using the Outback device--a report of 2 cases.
Клинический случайСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Kirk James, Wilson Richard, Kovacs Flora, Tennant William, Braithwaite Bruce, Habib Said
Аннотация
INTRODUCTION: We report 2 cases where the Outback catheter facilitated extra-anatomical bypass after vessel perforation during attempted subintimal vessel dissection.
REPORT: Attempted subintimal angioplasty of the superficial femoral artery (SFA) resulted in vessel perforation in 2 patients with chronic SFA occlusion and limb ischemia. Due to the lack of other endovascular or surgical options, the Outback catheter was used to reenter the patent lumen distal to the perforation. A stent graft was then deployed from proximal to the perforation to beyond the reentry point with successful outcomes.
DISCUSSION: Although the reentry devices are typically used to enter the lumen from the subintimal plane, this novel technique involves using the Outback catheter to enter from the extravascular compartment and facilitate bypass of the SFA occlusion via an extra-anatomical route. This novel technique can be used to restore in-line blood flow when attempted endovascular revascularization failed due to vessel perforation.
REPORT: Attempted subintimal angioplasty of the superficial femoral artery (SFA) resulted in vessel perforation in 2 patients with chronic SFA occlusion and limb ischemia. Due to the lack of other endovascular or surgical options, the Outback catheter was used to reenter the patent lumen distal to the perforation. A stent graft was then deployed from proximal to the perforation to beyond the reentry point with successful outcomes.
DISCUSSION: Although the reentry devices are typically used to enter the lumen from the subintimal plane, this novel technique involves using the Outback catheter to enter from the extravascular compartment and facilitate bypass of the SFA occlusion via an extra-anatomical route. This novel technique can be used to restore in-line blood flow when attempted endovascular revascularization failed due to vessel perforation.