MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.23407

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2011

In vivo comparison of a polymer-free Biolimus A9-eluting stent with a biodegradable polymer-based Biolimus A9 eluting stent and a bare metal stent in balloon denuded and radiated hypercholesterolemic rabbit iliac arteries.

Waksman Ron, Pakala Rajbabu, Baffour Richard, Seabron Rufus, Hellinga David, Chan Rosanna, Su Shih-Horng, Kolodgie Frank, Virmani Renu

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To evaluate the effect of a polymer-free Biolimus A9-eluting stent [BioFreedom (BF)], compared with that of a biodegradable polymer-based Biolimus A9-eluting stent [BioMatrix Flex (BMF)] and a bare metal stent (BMS) in balloon denuded and radiated hypercholesterolemic rabbit iliac arteries.

METHODS

Rabbits were fed with 1% cholesterol diet (n = 14) for 14 days, both iliac arteries were balloon denuded and radiated, and then rabbits were switched to 0.15% cholesterol diet. After 4 weeks, BF (n = 8), BMF (n = 8), and BMS (n = 8) were deployed in denuded and radiated areas. Four weeks later animals were euthanized, arterial segments were processed for morphometry.

RESULTS

The neointimal area in vessels implanted with BF stents was significantly less than that seen in vessels implanted with BMS (0.90 mm(2) ± 0.14 vs. 1.29 mm(2) ± 0.23, P <0.01). Percent fibrin and fibrin score were higher with BMF stents compared to BMS (P <0.03 and <0.04) and giant cell number was significantly higher with both BMF and BF stents (P < 0.01 for both). Percent endothelialization was significantly higher and % uncovered struts were lower with BMS compared to either BMF or BF stents (P < 0.05 for both).

CONCLUSION

This study demonstrates that compared to BMS, BF stents significantly decreased neointimal hyperplasia.

Для цитирования: Waksman Ron, Pakala Rajbabu, Baffour Richard, Seabron Rufus, Hellinga David, Chan Rosanna, Su Shih-Horng, Kolodgie Frank, Virmani Renu. In vivo comparison of a polymer-free Biolimus A9-eluting stent with a biodegradable polymer-based Biolimus A9 eluting stent and a bare metal stent in balloon denuded and radiated hypercholesterolemic rabbit iliac arteries.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2011. DOI: 10.1002/ccd.23407.