Oxygen reserve index versus conventional peripheral oxygen saturation for prevention of hypoxaemia: A randomised controlled trial.

Kim Eun-Hee, Park Jung-Bin, Kang Pyoyoon, Ji Sang-Hwan, Jang Young-Eun, Lee Ji-Hyun, Kim Hee-Soo, Kim Jin-Tae

СтатьяРандомизированное исследованиеСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Hypoxaemia occurs frequently during paediatric laryngeal microsurgery.

OBJECTIVE

The oxygen reserve index is a noninvasive and continuous parameter to assess PaO2 levels in the range of 100 to 200 mmHg. It ranges from 0 to 1.0. We investigated whether monitoring the oxygen reserve index can reduce the incidence of SpO2 90% or less.

DESIGN

Randomised controlled trial.

SETTING

A tertiary care paediatric hospital.

PARTICIPANTS

Paediatric patients aged 18 years or less scheduled to undergo laryngeal microsurgery.

INTERVENTION: The patients were randomly allocated to the oxygen reserve index or control groups, and stratified based on the presence of a tracheostomy tube. Rescue intervention was performed when the oxygen reserve index was 0.2 or less and the SpO2 was 94% or less in the oxygen reserve index and control groups, respectively.

MAIN OUTCOME MEASURE: The primary outcome was the incidence of SpO2 90% or less during the surgery.

RESULTS

Data from 88 patients were analysed. The incidence of SpO2 ≤ 90% did not differ between the oxygen reserve index and control groups [P = 0.114; 11/44, 25% vs. 18/44, 40.9%; relative risk: 1.27; and 95% confidence interval (CI): 0.94 to 1.72]. Among the 128 rescue interventions, SpO2 ≤ 90% event developed in 18 out of 75 events (24%) and 42 out of 53 events (79.2%) in the oxygen reserve index and control groups, respectively (P < 0.001; difference: 55.2%; and 95% CI 38.5 to 67.2%). The number of SpO2 ≤ 90% events per patient in the oxygen reserve index group (median 0, maximum 3) was less than that in the control group (median 0, maximum 8, P = 0.031).

CONCLUSION

Additional monitoring of the oxygen reserve index, with a target value of greater than 0.2 during paediatric airway surgery, alongside peripheral oxygen saturation, did not reduce the incidence of SpO2 ≤ 90%.

Для цитирования: Kim Eun-Hee, Park Jung-Bin, Kang Pyoyoon, Ji Sang-Hwan, Jang Young-Eun, Lee Ji-Hyun, Kim Hee-Soo, Kim Jin-Tae. Oxygen reserve index versus conventional peripheral oxygen saturation for prevention of hypoxaemia: A randomised controlled trial.. European journal of anaesthesiology. 2024. DOI: 10.1097/eja.0000000000002018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.