m+Medelevator.RU
← Поиск публикаций
ACS chemical neuroscience · 2020

Test-Retest Repeatability of [18F]MC225-PET in Rodents: A Tracer for Imaging of P-gp Function.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

García-Varela Lara, Vállez García David, Rodríguez-Pérez Manuel, van Waarde Aren, Sijbesma Jürgen W A, Schildt Anna, Kwizera Chantal, Aguiar Pablo, Sobrino Tomás, Dierckx Rudi A J O, Elsinga Philip H, Luurtsema Gert

Аннотация

In longitudinal PET studies, animals are repeatedly anesthetized which may affect the repeatability of PET measurements. The aim of this study was to assess the effect of anesthesia on the P-gp function as well as the reproducibility of [18F]MC225 PET scans. Thus, dynamic PET scans with blood sampling were conducted in 13 Wistar rats. Seven animals were exposed to isoflurane anesthesia 1 week before the PET scan ("Anesthesia-exposed" PET). A second group of six animals was used to evaluate the reproducibility of measurements of P-gp function at the blood-brain barrier (BBB) with [18F]MC225. In this group, two PET scans were made with a 1 week interval ("Test" and "Retest" PET). Pharmacokinetic parameters were calculated using compartmental models and metabolite-corrected plasma as an input function. "Anesthesia-exposed" animals showed a 28% decrease in whole-brain volume of distribution (VT) (p < 0.001) compared to "Test", where the animals were not previously anesthetized. The VT at "Retest" also decreased (19%) compared to "Test" (p < 0.001). The k2 values in whole-brain were significantly increased by 18% in "Anesthesia-exposed" (p = 0.005) and by 15% in "Retest" (p = 0.008) compared to "Test". However, no significant differences were found in the influx rate constant K1, which is considered as the best parameter to measure the P-gp function. Moreover, Western Blot analysis did not find significant differences in the P-gp expression of animals not pre-exposed to anesthesia ("Test") or pre-exposed animals ("Retest"). To conclude, anesthesia may affect the brain distribution of [18F]MC225 but it does not affect the P-gp expression or function.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты