MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mnm.0000000000001099

Медицинская библиотека · Nuclear medicine communications · 2019

Comparison of glomerular filtration rates determined using two- and single-blood sample methods with a three-blood sample technique for 2922 paediatric studies.

Bibbo Giovanni, Munn Catherine, Kirkwood Ian

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Several different methods for measuring glomerular filtration rates (GFRs) have been developed in search of a more accurate and simplified technique. Currently, the main methods used are the slope-intercept and distribution volume techniques. In this work, 2922 GFR studies have been retrospectively reanalysed as two- and single-blood sample methods and compared with the three-blood sample data.

PATIENTS AND

METHODS

Paediatric GFR data from 1/1/1993 to 4/12/2018 using the three-blood sample technique have been reanalysed as two- and single-blood sample methods. The timing of blood sampling was also reviewed.

RESULTS

Both the two- and the single-sample methods provide accurate estimates of GFR in children for all levels of renal function provided that the blood samples are collected at the appropriate times post administration of the tracer. For the highest accuracy, blood for the two-blood samples method should be collected at 2 and 4 h and at 2 h for the single-blood sample method. The relationship between renal clearance and the 2-h volume of distribution (V120) is linear with a line of best fit: GFR (ml/min) = 3.108 × V120 - 2.557.

CONCLUSION

Both the two- and the single-sample techniques can be used to measure GFR in children with the same accuracy as the three-blood sample. With the collection of only a single-blood sample, there are benefits to all involved: patients, families, and nuclear medicine personnel. In addition, institutions have a choice as to which technique to use and for which patients.

Для цитирования: Bibbo Giovanni, Munn Catherine, Kirkwood Ian. Comparison of glomerular filtration rates determined using two- and single-blood sample methods with a three-blood sample technique for 2922 paediatric studies.. Nuclear medicine communications. 2019. DOI: 10.1097/mnm.0000000000001099.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.