MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11604-025-01789-3

Медицинская библиотека · Japanese journal of radiology · 2025

Evaluation of amyloid PET positivity using machine learning on 18F-FDG PET images.

Yamada Takahiro, Kimura Yuichi, Watanabe Shogo, Watanabe Aya, Honda Misa, Nagaoka Takashi, Nemoto Mitsutaka, Hanaoka Kohei, Kaida Hayato, Kojita Yasuyuki, Yamada Minoru, Im SungWoon, Kono Atsushi, Ishii Kazunari

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Since the approval of disease-modifying drugs for Alzheimer's disease, the demand for amyloid positron emission tomography (PET) scans, which are crucial for determining treatment eligibility, is expected to increase significantly. We thus investigated the ability of an algorithm to predict amyloid accumulation from 18F-fluorodeoxyglucose (FDG)-PET images for use in amyloid PET screening.

METHODS

We analyzed the images of 194 subjects with cognitive disorders who had undergone brain FDG-PET, amyloid PET using Pittsburgh compound-B (11C-PiB), and MRI scans at Kindai University Hospital between 2011 and 2018. Among them, 108 subjects showed positive amyloid accumulation; the other 86 did not. For the 108 positive cases, the input values were the region of interest-based calculated from the automatic anatomical labeling template, which divides the brain into 120 regions, and applied to the anatomically standardized FDG-PET images of each subject. We then used a support vector machine (SVM) machine learning algorithm and conducted a tenfold cross-validation to assess the algorithm's accuracy for predicting amyloid accumulation from FDG-PET images.

RESULTS

We observed 81.5% accuracy, 78.5% sensitivity, 84.6% specificity, and an area under the curve (AUC) of 0.846 during training. The validation results for the trained model revealed 85.9% accuracy, 88.4% sensitivity, 81.0% specificity, and an AUC of 0.918.

CONCLUSION

These results indicate that the performance of our algorithm to predict amyloid accumulation from 18FDG-PET images is adequate for use in amyloid PET scan screenings.

Для цитирования: Yamada Takahiro, Kimura Yuichi, Watanabe Shogo, Watanabe Aya, Honda Misa, Nagaoka Takashi, Nemoto Mitsutaka, Hanaoka Kohei, Kaida Hayato, Kojita Yasuyuki, Yamada Minoru, Im SungWoon, Kono Atsushi, Ishii Kazunari. Evaluation of amyloid PET positivity using machine learning on 18F-FDG PET images.. Japanese journal of radiology. 2025. DOI: 10.1007/s11604-025-01789-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.