MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/nmo.15004

Медицинская библиотека · Neurogastroenterology and motility · 2025

The Vibrating Capsule: Safety and Tolerability in Patients With Chronic Idiopathic Constipation.

Curtin Bryan F, Quigley Eamonn M M, Chey William D, Lembo Anthony J, Brenner Darren M, Spiegel Brennan M R, Rao Satish S C

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Chronic idiopathic constipation (CIC) remains a significant problem globally with increasing estimates for disease burden. In a Phase 3 placebo-controlled trial, a novel treatment using the Vibrating Capsule was recently shown to be effective in treating patients with CIC. However, its safety and tolerability has not been described in detail.

METHODS

We analyzed safety data from six trials encompassing the development of the Vibrating Capsule, including, dose-ranging and pivotal studies. The incidence of adverse events, treatment discontinuation, tolerability and satisfaction were assessed.

KEY

RESULTS

A total of 800 patients who took either an active Vibrating Capsule or a sham/placebo (non-vibrating) but similar capsule from 6 studies were included in this post hoc analysis. The most common adverse gastrointestinal events were bloating (2.9%), abdominal pain (2.9%), nausea (2.3%) and diarrhea (1.9%). A sensation of vibration was reported by 11.7% of patients. The adverse events rates were low, and investigators categorized most of them as unrelated to treatment. There were no serious adverse events such as retention of therapeutic capsules and no patient stopped therapy or withdrew due to adverse effects. The majority of patients (83%) found the system convenient, with an overall treatment satisfaction rate of 71%.

CONCLUSIONS AND INFERENCES: The Vibrating Capsule, a first in class treatment for CIC was found to be safe and well tolerated by patients in clinical trials. No patient discontinued treatment due to adverse events.

Для цитирования: Curtin Bryan F, Quigley Eamonn M M, Chey William D, Lembo Anthony J, Brenner Darren M, Spiegel Brennan M R, Rao Satish S C. The Vibrating Capsule: Safety and Tolerability in Patients With Chronic Idiopathic Constipation.. Neurogastroenterology and motility. 2025. DOI: 10.1111/nmo.15004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.