MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/bpb.0000000000001349

Медицинская библиотека · Journal of pediatric orthopedics. Part B · 2026

How reliable are radiographic measures of the pediatric elbow? Measurement and comparison of four parameters in healthy children's elbow.

Değer Göker Utku, Davutluoğlu Ece, Ayoğlu Nuri, Özşahin Mahmut Kürşat, Şeker Ali

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

The reproducibility of radiographic parameters used to assess pediatric supracondylar fracture reduction, including Baumann angle, lateral capitellohumeral angle (LCHA), carrying angle, and anterior humeral line (AHL) crossing the capitellum, was evaluated. Two observers undertook a total of 2368 measures on 148 elbow radiographs from 107 patients aged 0-12 years. The observers, who were blinded to their own measurements and each other's measurements, performed the measurements twice with a 1-month interval using an electronic goniometer. The average value and reliability of the measurements were evaluated. Intraobserver and interobserver reliability were determined using intraclass correlation coefficients (ICCs). The mean LCHA of the 148 elbow population was 52.4° (range: 27-74°), the mean Baumann angle was 71.5° (range: 54-90°), and the mean carrying angle was 18° (range: 5-37°). 80% of the AHL was in the middle third of the capitellum. The ICCs for interobserver reliability were moderate to good for Baumann angle 0.71-0.78, for LCHA 0.72-0.72, for carrying angle 0.83-0.85, and for AHL 0.89-0.90. The ICCs for intraobserver reliability were moderate to excellent for Baumann angle 0.93-0.86, for LCHA 0.91-0.81, for carrying angle 0.71-0.92, and for AHL 0.94-0.90. This study demonstrated that Baumann angle, LCHA, carrying angle, and AHL are reliable measuring methods, with normal values reported in the Turkish population.

Для цитирования: Değer Göker Utku, Davutluoğlu Ece, Ayoğlu Nuri, Özşahin Mahmut Kürşat, Şeker Ali. How reliable are radiographic measures of the pediatric elbow? Measurement and comparison of four parameters in healthy children's elbow.. Journal of pediatric orthopedics. Part B. 2026. DOI: 10.1097/bpb.0000000000001349.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.