MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12350-013-9802-3

Медицинская библиотека · Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2013

Is regadenoson an appropriate stressor for MPI in patients with left bundle branch block or pacemakers?

Thomas Gregory S, Kinser Carissa R, Kristy Rita, Xu Jiaqiong, Mahmarian John J

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Patients with LBBB or ventricular pacemaker undergoing MPI are at risk for false positive MPI results in the setting of an elevated heart rate (HR) with exercise or dobutamine stress. The areas of increased apparent ischemia are typically the LAD and septal territories.

METHODS

In a subanalysis of the ADVANCE MPI 1 and 2 studies, perfusion on an initial adenosine and a second MPI study with regadenoson or adenosine was compared by visual and quantitative analysis. Among 2,015 patients, 64 had LBBB and 93 had pacemakers. The hemodynamic response during the second scan was compared in those with and without LBBB and PM.

RESULTS

Following regadenoson, peak HR in the LBBB group increased by a mean of 25.4 compared to 15.3 bpm following adenosine (P = .0083). In the pacemaker group HR was blunted, 11.8 and 8.1 following regadenoson and adenosine, respectively (P = .1262). However, the visually assessed summed difference score and the quantitatively assessed extent of ischemia for the LAD and septal territories and the entire LV did not differ between the initial adenosine and subsequent regadenoson scans.

CONCLUSIONS

The significant increase in HR observed with regadenoson compared to adenosine did not translate into greater perfusion defects in the LAD or septal territories in patients undergoing regadenoson stress.

Для цитирования: Thomas Gregory S, Kinser Carissa R, Kristy Rita, Xu Jiaqiong, Mahmarian John J. Is regadenoson an appropriate stressor for MPI in patients with left bundle branch block or pacemakers?. Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology. 2013. DOI: 10.1007/s12350-013-9802-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.