BACKGROUND

The efficacy and safety of abciximab were investigated in Japanese patients undergoing percutaneous coronary intervention (PCI) for acute myocardial infarction (MI) or unstable angina.

METHODS AND

RESULTS

The 973 patients were randomized into 3 groups: the low-dose group (L group) received bolus injection of 0.20 mg/kg followed by 12-h infusion; the high-dose group (H group) received bolus injection of 0.25 mg/kg followed by 12-h infusion; the placebo group (P group) received bolus and infusion of placebo. The incidence of the primary endpoint (30-day post-PCI coronary events: death, MI or urgent revascularization) was 3.6%, 1.6%, and 4.1% in the P, L, and H groups, respectively, with no significant difference between the P and L groups (P=0.104) or between the P and H groups (P=0.772). The incidence of bleeding tended to increase in a dose-dependent manner.

CONCLUSION

No significant difference in the incidence of coronary events was found between the placebo and abciximab groups, so the efficacy of abciximab in preventing post-PCI coronary events in Japanese patients was not confirmed.

Для цитирования: Nakagawa Yoshihisa, Nobuyoshi Masakiyo, Yamaguchi Tetsu, Meguro Taiichiro, Yokoi Hiroyoshi, Kimura Takeshi, Hosoda Saichi, Kanmatsuse Katsuo, Matsumori Akira, Sasayama Shigetake. Efficacy of abciximab for patients undergoing balloon angioplasty: data from Japanese evaluation of c7E3 Fab for elective and primary PCI organization in randomized trial (JEPPORT).. Circulation journal : official journal of the Japanese Circulation Society. 2008. DOI: 10.1253/circj.cj-08-0560.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.