PURPOSE: To compare optic disc parameters when using manual disc detection versus automated software on RTVue-100 Fourier-domain optical coherence tomography.

METHODS

Nonrandomized comparative study using images obtained from a tertiary-care Glaucoma Clinic from August, 2008 to May, 2009. Four hundred thirty-four patients with mean age of 67.1 years (±13.4) underwent OCT imaging with RTVue-100. Optic disc margins were manually defined by a single, trained operator and redefined with automated software that estimates the position of the retinal pigment epithelium edges. Bland-Altman plots and intraclass correlations measured agreement between the 2 detection methods for various optic disc parameters.

RESULTS

Bland-Altman plots/intraclass correlations showed good agreement in the following optic disc parameters: optic disc area, cup area, rim area, cup-to-disc area ratio, cup-to-disc ratio, and retinal nerve fiber layer thickness. There was no significant difference in measurements when comparing hand versus automated disc contour determination (P>0.05).

CONCLUSIONS

Automated determination of the disc margin was in high agreement with subjective, manual assessment and should be used in clinical practice as it can make optical coherence tomography scanning more efficient and standardized, as disc detection would only be done by the software and not biased by multiple operators.

Для цитирования: Mesiwala Nisreen K, Pekmezci Melike, Porco Travis C, Lin Shan C. Optic disc parameters from optovue optical coherence tomography: comparison of manual versus automated disc rim determination.. Journal of glaucoma. 2012. DOI: 10.1097/ijg.0b013e31821206e8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.