MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5114/pedm.2021.107717

Медицинская библиотека · Pediatric endocrinology, diabetes, and metabolism · 2021

Continuous glucose monitoring systems in well-controlled children with type 1 diabetes mellitus.

M Kowalczyk Emilia, Adamczyk Marta, Pietrzyk Justyna, Jastrzębska Barbara, Szypowska Agnieszka

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Numerous studies have demonstrated the clinical benefits of using continuous glucose monitoring (CGM) systems among patients with type 1 diabetes (T1D). Aim of the study was to assess the effectiveness of CGM on metabolic control in children with T1D and well-controlled disease prior to the study.

MATERIAL AND

METHODS

This prospective analysis included 99 children (46 girls) at the median age of 11.23 years and diabetes duration of at least 1 year (median: 5.16 years), generally well controlled metabolically (median HbA1c: 7.0%), and treated with continuous subcutaneous insulin infusion (CSII). The patients had used CGM for at least 150 days. We analysed the participants in subgroups based on baseline HbA1c < 7%, ≥ 7%, age, and sex.

RESULTS

Children with baseline HbA1c < 7% were characterized by significantly increased HbA1c after the median of 273 days (217; 320) of CGM usage (6.3% vs. 6.6%, respectively; p = 0.002). No significant change in HbA1c was noted in children with baseline HbA1c ≥ 7% (7.5% vs. 7.4%, respectively; p = 0.191), but 20% of the group reached the target of HbA1c < 7.0%. The analysis of CGM data revealed that no group achieved the CGM targets of good metabolic control. Total daily insulin requirements remained stable in both groups (p = 0.752; p = 0.274), but the amount of basal insulin increased statistically in both groups (p = 0.009; p ≤ 0.001).

CONCLUSIONS

The application of CGM provides detailed information concerning glycaemic control and is beneficial in some, but not all, T1D children with good diabetes control.

Для цитирования: M Kowalczyk Emilia, Adamczyk Marta, Pietrzyk Justyna, Jastrzębska Barbara, Szypowska Agnieszka. Continuous glucose monitoring systems in well-controlled children with type 1 diabetes mellitus.. Pediatric endocrinology, diabetes, and metabolism. 2021. DOI: 10.5114/pedm.2021.107717.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.