DOI 10.1109/tbme.2018.2852715

Медицинская библиотека · IEEE transactions on bio-medical engineering · 2018

In-Vivo Evaluation of Microultrasound and Thermometric Capsule Endoscopes.

Lay Holly S, Cummins Gerard, Cox Benjami F, Qiu Yongqiang, Turcanu Mihnea Vlad, McPhillips Rachael, Connor Ciaran, Gregson Rachael, Clutton Eddie, Desmulliez Marc P Y, Cochran Sandy

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Clinical endoscopy and colonoscopy are commonly used to investigate and diagnose disorders in the upper gastrointestinal tract and colon, respectively. However, examination of the anatomically remote small bowel with conventional endoscopy is challenging. This and advances in miniaturization led to the development of video capsule endoscopy (VCE) to allow small bowel examination in a noninvasive manner. Available since 2001, current capsule endoscopes are limited to viewing the mucosal surface only due to their reliance on optical imaging. To overcome this limitation with submucosal imaging, work is under way to implement microultrasound (μUS) imaging in the same form as VCE devices. This paper describes two prototype capsules, termed Sonocap and Thermocap, which were developed respectively to assess the quality of μUS imaging and the maximum power consumption that can be tolerated for such a system. The capsules were tested in vivo in the oesophagus and small bowel of porcine models. Results are presented in the form of μUS B-scans as well as safe temperature readings observed up to 100 mW in both biological regions. These results demonstrate that acoustic coupling and μUS imaging can be achieved in vivo in the lumen of the bowel and the maximum power consumption that is possible for miniature μUS systems.

Для цитирования: Lay Holly S, Cummins Gerard, Cox Benjami F, Qiu Yongqiang, Turcanu Mihnea Vlad, McPhillips Rachael, Connor Ciaran, Gregson Rachael, Clutton Eddie, Desmulliez Marc P Y, Cochran Sandy. In-Vivo Evaluation of Microultrasound and Thermometric Capsule Endoscopes.. IEEE transactions on bio-medical engineering. 2018. DOI: 10.1109/tbme.2018.2852715.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.