MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00056-010-0005-0

Медицинская библиотека · Journal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie · 2011

Measuring mesiodistal width of impacted maxillary canines: CT-assisted determination.

Hofmann Elisabeth, Medelnik Jürgen, Keller Thomas, Steinhäuser Stefanie, Hirschfelder Ursula

СтатьяПеревод пока не подготовлен

Аннотация

AIM: Precise, three-dimensional localization of impacted maxillary canines is central to their clinical management. Predicting precisely the crown's mesiodistal width is paramount in planning orthodontic treatment. The aim of this study was to verify the exact mesiodistal width of impacted canines via MSCT (multislice spiral computed tomography) examinations.

PATIENTS AND

METHODS

3D MSCT images from 17 patients with a total of 24 impacted maxillary canines were taken to obtain the largest mesiodistal diameter using mesial and distal contact points. All existing maxillary canines were included in this study. Mesiodistal tooth width was also determined using callipers on a plaster model after canine eruption. Each measurement was taken twice by 3 observers after a 10-day interval. Statistical analysis entailed calculating and comparing the systematic error, intrarater and interrater standard deviations (Deming regression and ANOVA with random effects).

RESULTS

Comparison of the different methods revealed good agreement between the pre-eruption and post-eruption values regarding the canine's mesiodistal width. Total standard deviation was 0.16 mm for values obtained from MSCT measurements and 0.12 mm for those taken with callipers. For both methods intrarater measurement error differed by a factor of 2 (repeatability; model versus MSCT: 0.07 mm versus 0.12 mm), while interrater deviation did not differ significantly (reproducibility; model versus MSCT: 0.10 mm versus 0.10 mm). The reproducibility of our measurements whether taken on the model or with CT was below biological variability.

CONCLUSIONS

The volumetric data from an MSCT system gives highly accurate information on the mesiodistal width of displaced canines.

Для цитирования: Hofmann Elisabeth, Medelnik Jürgen, Keller Thomas, Steinhäuser Stefanie, Hirschfelder Ursula. Measuring mesiodistal width of impacted maxillary canines: CT-assisted determination.. Journal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie. 2011. DOI: 10.1007/s00056-010-0005-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.