Clinical performance of the Osia™ system, a new active osseointegrated implant system. Results from a prospective clinical investigation.

Goycoolea Marcos, Ribalta Gloria, Tocornal Francisco, Levy Raquel, Alarcón Pilar, Bryman Martin, Cagnacci Byanka, Catenacci Catherine, Oyanguren Valeria, Vilches Ignacia, Briones Verónica, García Raimundo

СтатьяПеревод в очереди

Аннотация

Background

Bone-conduction hearing implants are standard of care devices.Aims/

Objectives

Evaluation of a new active magnetic bone-conduction hearing implant: Cochlear Osia™ system.Material and methods: This device uses a transcutaneous connection between an external sound-processor and an osseointegrated implant that generates vibrations using a piezoelectricity-based internal bone-conduction system. Nine patients with conductive-hearing loss were implanted. Surgical efficacy, hearing performance and quality-of-life were evaluated. Hearing performance in quiet and in noise was compared with unaided hearing and hearing with the Baha 5 Power® Sound Processor on a softband.

Results

Surgery and healing were uneventful. Statistically significant improvements in audibility, speech-understanding, speech-recognition and quality-of-sound in noise and quiet were found for the Osia™ compared to preoperative unaided hearing and aided hearing with the Baha 5 Power® Sound Processor on a softband. The active vibration system provided improvement at low and high frequencies. At 6 months postoperatively, all patients continue to use the device.Conclusions and significance: The Osia™ is safe and effective, improving speech-recognition in quiet and in noise, at low and high frequencies, thus delivering better quality-of-hearing than passive devices.

Для цитирования: Goycoolea Marcos, Ribalta Gloria, Tocornal Francisco, Levy Raquel, Alarcón Pilar, Bryman Martin, Cagnacci Byanka, Catenacci Catherine, Oyanguren Valeria, Vilches Ignacia, Briones Verónica, García Raimundo. Clinical performance of the Osia™ system, a new active osseointegrated implant system. Results from a prospective clinical investigation.. Acta oto-laryngologica. 2020. DOI: 10.1080/00016489.2019.1691744.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.