MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12911-023-02215-2

Медицинская библиотека · BMC medical informatics and decision making · 2023

Non-invasive arterial blood pressure measurement and SpO2 estimation using PPG signal: a deep learning framework.

Chu Yan, Tang Kaichen, Hsu Yu-Chun, Huang Tongtong, Wang Dulin, Li Wentao, Savitz Sean I, Jiang Xiaoqian, Shams Shayan

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Monitoring blood pressure and peripheral capillary oxygen saturation plays a crucial role in healthcare management for patients with chronic diseases, especially hypertension and vascular disease. However, current blood pressure measurement methods have intrinsic limitations; for instance, arterial blood pressure is measured by inserting a catheter in the artery causing discomfort and infection.

METHOD: Photoplethysmogram (PPG) signals can be collected via non-invasive devices, and therefore have stimulated researchers' interest in exploring blood pressure estimation using machine learning and PPG signals as a non-invasive alternative. In this paper, we propose a Transformer-based deep learning architecture that utilizes PPG signals to conduct a personalized estimation of arterial systolic blood pressure, arterial diastolic blood pressure, and oxygen saturation.

RESULTS

The proposed method was evaluated with a subset of 1,732 subjects from the publicly available ICU dataset MIMIC III. The mean absolute error is 2.52 ± 2.43 mmHg for systolic blood pressure, 1.37 ± 1.89 mmHg for diastolic blood pressure, and 0.58 ± 0.79% for oxygen saturation, which satisfies the requirements of the Association of Advancement of Medical Instrumentation standard and achieve grades A for the British Hypertension Society standard.

CONCLUSIONS

The results indicate that our model meets clinical standards and could potentially boost the accuracy of blood pressure and oxygen saturation measurement to deliver high-quality healthcare.

Для цитирования: Chu Yan, Tang Kaichen, Hsu Yu-Chun, Huang Tongtong, Wang Dulin, Li Wentao, Savitz Sean I, Jiang Xiaoqian, Shams Shayan. Non-invasive arterial blood pressure measurement and SpO2 estimation using PPG signal: a deep learning framework.. BMC medical informatics and decision making. 2023. DOI: 10.1186/s12911-023-02215-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.