MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.gie.2010.06.041

Медицинская библиотека · Gastrointestinal endoscopy · 2010

Self-expanding removable plastic stents for the protection of surgical anastomoses after esophageal replacement in a porcine model.

Le Baleur Yann, Gaujoux Sébastien, Bruneval Patrick, Lambert Benoît, Larghero Jérome, Cattan Pierre, Prat Frédéric

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Esophageal replacement by biological graft is associated with a high risk of anastomotic leak-related mediastinitis.

OBJECTIVE

To determine whether a self-expanding plastic stent can help avoid anastomotic leak after full-thickness replacement of the esophagus in a porcine model.

DESIGN

Experimental feasibility study in a porcine model.

SUBJECTS: Twelve pigs were analyzed in the study.

INTERVENTIONS: Replacement of a 2-cm-long segment of the cervical esophagus by an aortic allograft was performed in 12 pigs, with 6 pigs used as graft donors. Animals were divided into 2 groups depending on whether a self-expanding removable plastic stent protecting the 2 aortoesophageal anastomoses was inserted (n = 7) or not (n = 5), and were allowed to eat 24 hours postoperatively.

MAIN OUTCOME MEASUREMENTS: The relative occurrence of mediastinitis caused by anastomotic leakage in stented and nonstented groups was assessed; endoscopic evaluation and histological analysis of the graft area were performed 1 month after esophageal replacement.

RESULTS

All animals (n = 5) without stent insertion died of anastomotic leakage within 20 days of surgery. Two of the 7 stented animals died at day 2, and 5 survived 1 month in good clinical condition. Two stent migrations were noted. Stent extraction was followed by the development of a fibrous stricture.

CONCLUSIONS

The use of a self-expanding plastic stent seems to allow leak-free healing after circumferential replacement of the esophagus by a biological graft in a porcine model.

Для цитирования: Le Baleur Yann, Gaujoux Sébastien, Bruneval Patrick, Lambert Benoît, Larghero Jérome, Cattan Pierre, Prat Frédéric. Self-expanding removable plastic stents for the protection of surgical anastomoses after esophageal replacement in a porcine model.. Gastrointestinal endoscopy. 2010. DOI: 10.1016/j.gie.2010.06.041.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.