Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2010
Pulmonary artery stents: long-term follow-up.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Law Mark A, Shamszad Pirouz, Nugent Alan W, Justino Henri, Breinholt John P, Mullins Charles E, Ing Frank F
Аннотация
OBJECTIVES: Determine the long-term outcomes of branch pulmonary artery (PA) stents.
BACKGROUND: PA stents in congenital heart disease effectively relieve stenoses in the short-term. Published long-term data are limited.
METHODS: Patients enrolled in an FDA IDE protocol from 1989-92 were included. Clinical follow-up and catheterization data were evaluated. Patients were included if >5 year follow-up data was available or if mortality occurred following the initial procedure.
RESULTS: There were five deaths: four due to progression of their underlying heart disease, and one from a complication during a follow-up catheterization. Clinical data for 43 surviving patients demonstrated 39 patients (91%) are in NYHA class I or II. Seven patients underwent surgical intervention during the follow-up period (five RV-PA conduit, two Fontan revisions), but none addressed PA stenosis. Final repeat catheterizations were performed in 36 patients (55 stents) 7.2 +/- 4.3 years post stent insertion with 1.2 +/- 0.9 further procedures with stent dilations. In this subgroup, the minimum vessel diameter increased from 4.7 +/- 1.8 to 13.4 +/- 2.4 mm (P < 0.001), and the pressure gradient improved from 41 +/- 25 to 9 +/- 11 mm Hg (P < 0.001). Higher initial gradient and smaller balloons were associated with a final stent diameter of <14 mm (P = 0.030 and 0.046). Jailed vessels occurred in 49% of stents with abnormal angiographic flow in 18/55. Six repeat catheterizations resulted in complications, including the one procedural death.
CONCLUSION: Stents implants for PA stenoses provide effective improvement in vessel caliber in the long-term. Although repeat interventions are necessary, this procedure reduces RV pressure and provides an important alternative to surgery for residual PA obstruction.
BACKGROUND: PA stents in congenital heart disease effectively relieve stenoses in the short-term. Published long-term data are limited.
METHODS: Patients enrolled in an FDA IDE protocol from 1989-92 were included. Clinical follow-up and catheterization data were evaluated. Patients were included if >5 year follow-up data was available or if mortality occurred following the initial procedure.
RESULTS: There were five deaths: four due to progression of their underlying heart disease, and one from a complication during a follow-up catheterization. Clinical data for 43 surviving patients demonstrated 39 patients (91%) are in NYHA class I or II. Seven patients underwent surgical intervention during the follow-up period (five RV-PA conduit, two Fontan revisions), but none addressed PA stenosis. Final repeat catheterizations were performed in 36 patients (55 stents) 7.2 +/- 4.3 years post stent insertion with 1.2 +/- 0.9 further procedures with stent dilations. In this subgroup, the minimum vessel diameter increased from 4.7 +/- 1.8 to 13.4 +/- 2.4 mm (P < 0.001), and the pressure gradient improved from 41 +/- 25 to 9 +/- 11 mm Hg (P < 0.001). Higher initial gradient and smaller balloons were associated with a final stent diameter of <14 mm (P = 0.030 and 0.046). Jailed vessels occurred in 49% of stents with abnormal angiographic flow in 18/55. Six repeat catheterizations resulted in complications, including the one procedural death.
CONCLUSION: Stents implants for PA stenoses provide effective improvement in vessel caliber in the long-term. Although repeat interventions are necessary, this procedure reduces RV pressure and provides an important alternative to surgery for residual PA obstruction.
Предметные рубрики MeSH
AdolescentAngioplasty, BalloonArterial Occlusive DiseasesCardiac Surgical ProceduresChildChild, PreschoolConstriction, PathologicFemaleFollow-Up StudiesHeart Defects, CongenitalHemodynamicsHumansMaleProsthesis DesignProsthesis FailurePulmonary ArteryRadiographyRecovery of FunctionStentsTime FactorsTreatment OutcomeUltrasonography