Self transglutaminase-based rapid coeliac disease antibody detection by a lateral flow method.

Raivio T, Kaukinen K, Nemes E, Laurila K, Collin P, Kovács J B, Mäki M, Korponay-Szabó I R

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The conventional coeliac disease antibody tests require patient's sera, and are laborious and time-consuming.

AIM: To evaluate a newly developed rapid whole blood test in coeliac disease antibody detection, and its suitability for office use.

METHODS

Endogenous tissue transglutaminase found in red blood cells in a whole blood fingertip or venous sample is liberated upon haemolysis and complexes with tissue transglutaminase antibodies, if present. The complexes, captured by a lateral flow system, are visualized within 5 min. Stored samples from 121 untreated, 106 treated coeliac disease patients and 107 controls were evaluated and compared with serum endomysium and tissue transglutaminase antibody tests and histology; 150 patients were prospectively tested on site in the doctor's office.

RESULTS

The rapid test showed sensitivity (96.7%) comparable with the serum endomysium and tissue transglutaminase antibody tests from stored samples; specificity was slightly lower (93.5%). When tested on site the results were concordant in 96.7% of cases compared with endomysium and tissue transglutaminase antibody results. The test recognized the disappearance of tissue transglutaminase antibodies on a gluten-free diet.

CONCLUSIONS

The self tissue transglutaminase-based rapid test can be easily carried out from a fingertip blood sample on site in the physician's office for both coeliac disease case finding and dietary monitoring purposes.

Для цитирования: Raivio T, Kaukinen K, Nemes E, Laurila K, Collin P, Kovács J B, Mäki M, Korponay-Szabó I R. Self transglutaminase-based rapid coeliac disease antibody detection by a lateral flow method.. Alimentary pharmacology & therapeutics. 2006. DOI: 10.1111/j.1365-2036.2006.02957.x.