MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.27526

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2018

Impact of sheath size and hemostasis time on radial artery patency after transradial coronary angiography and intervention in Japanese and non-Japanese patients: A substudy from RAP and BEAT (Radial Artery Patency and Bleeding, Efficacy, Adverse evenT) randomized multicenter trial.

Aminian Adel, Saito Shigeru, Takahashi Akihiko, Bernat Ivo, Jobe Robert Lee, Kajiya Takashi, Gilchrist Ian C, Louvard Yves, Kiemeneij Ferdinand, van Royen Niels, van Leeuwen Maarten, Yamazaki Seiji, Matsukage Takashi, Iglesias Juan F, Rao Sunil V

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

During transradial (TR) access, it remains unclear whether differences in baseline patients characteristics and hemostasis care impact the rate of radial artery occlusion (RAO). We sought to compare the rate of RAO after TR access with the 6 French(Fr) Glidesheath Slender (GSS6Fr, Terumo, Japan) or a standard 5 Fr sheath in Japanese and non-Japanese patients.

METHODS AND

RESULTS

The Radial Artery Patency and Bleeding, Efficacy, Adverse evenT (RAP and BEAT) trial randomized 1,836 patients undergoing TR coronary angiography and/or interventions to receive the GSS6Fr or the standard 5 Fr Glidesheath (GS5Fr, Terumo, Japan). Out of this study population, 1,087 were Japanese patients and 751 non-Japanese patients. The overall incidence of RAO was significantly higher in Japanese patients (3.6% vs. 1.2%, P = 0.002). Use of GSS6Fr was associated with higher rates of RAO than GS5Fr in Japanese patients (5% vs. 2.2%, P = 0.02) and with similar RAO rates in non-Japanese patients (1.3 vs. 1.1%, P = 1). The mean hemostasis time was significantly longer in Japanese patients (378 ± 253 vs. 159 ± 136 min, P < 0.001) and more Japanese patients had a hemostasis time of more than 6 hr (16.2% vs. 4.9%, P < 0.0001). Longer hemostasis time was an independent predictor of RAO (OR per additional hour 1.070, 95% CI 1.008-1.136, P = 0.03).

CONCLUSIONS

Use of GSS6Fr was associated with a higher rate of RAO than a standard 5 Fr sheath in Japanese patients but not in non-Japanese patients. Whether improvement in post-procedural care and reduced hemostasis time could impact the incidence of RAO in Japanese patients should be further assessed.

Для цитирования: Aminian Adel, Saito Shigeru, Takahashi Akihiko, Bernat Ivo, Jobe Robert Lee, Kajiya Takashi, Gilchrist Ian C, Louvard Yves, Kiemeneij Ferdinand, van Royen Niels, van Leeuwen Maarten, Yamazaki Seiji, Matsukage Takashi, Iglesias Juan F, Rao Sunil V. Impact of sheath size and hemostasis time on radial artery patency after transradial coronary angiography and intervention in Japanese and non-Japanese patients: A substudy from RAP and BEAT (Radial Artery Patency and Bleeding, Efficacy, Adverse evenT) randomized multicenter trial.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2018. DOI: 10.1002/ccd.27526.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.