MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/sc.2009.56

Медицинская библиотека · Spinal cord · 2009

The feasibility of using auto-titrating continuous positive airway pressure to treat obstructive sleep apnoea after acute tetraplegia.

Berlowitz D J, Spong Jo, Pierce R J, Ross J, Barnes M, Brown D J

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

STUDY

DESIGN

A prospective cohort with acute tetraplegia.

OBJECTIVES

Obstructive sleep apnoea (OSA) is common within weeks of tetraplegia. This study aimed at determining the feasibility of auto-titrating continuous positive airway pressure (CPAP) to treat OSA after acute tetraplegia.

SETTING

The Victorian Spinal Cord Service, Melbourne, Australia.

METHODS

Participants underwent full, portable polysomnography. Those with an apnoea hypopnoea index of more than 10 events per hour were defined as having OSA and were offered treatment with CPAP. Treatment adherence was objectively monitored, and measures of quality of life, sleepiness and functional outcomes were determined at enrollment and 3 months later at study conclusion.

RESULTS

A total of 44 patients were admitted to our Spinal Cord Service over 9 months, and 19 participated. Fourteen of them had OSA and seven were adherent with therapy for 3 months. Compared with those who did not have OSA, and with those with OSA who were not adherent with CPAP, those who adhered to CPAP were older (mean (s.d.) age 54 years (13) versus non-adherent 28 years (15) and no OSA 29 years (10)) and heavier (body mass index (BMI) 32.5 (11.7), 24.1 (3.7) and 20.6 (3.1), respectively). CPAP-adherant patients and those without OSA showed a 50% or greater improvement in their state sleepiness over the 3 months. Patients with OSA who did not tolerate CPAP had no improvement in sleepiness.

CONCLUSION

Auto-titrating CPAP is a feasible treatment for OSA in acute tetraplegia. Intensive clinical support was required initially, and a tolerance of therapy for at least 4 h for one of the first 3 days was predictive of good CPAP usage.

SPONSORSHIP: Transport Accident Commission.

Для цитирования: Berlowitz D J, Spong Jo, Pierce R J, Ross J, Barnes M, Brown D J. The feasibility of using auto-titrating continuous positive airway pressure to treat obstructive sleep apnoea after acute tetraplegia.. Spinal cord. 2009. DOI: 10.1038/sc.2009.56.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.