MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.vascn.2013.07.001

Медицинская библиотека · Journal of pharmacological and toxicological methods · 2013

The PEG-switch assay: a fast semi-quantitative method to determine protein reversible cysteine oxidation.

Burgoyne Joseph Robert, Oviosu Olujimi, Eaton Philip

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

INTRODUCTION

Reversible protein cysteine oxidation is recognised as a pivotal post-transitional modification that transduces physiological as well as pathological signalling. Pharmacological interventions that target specific sources of oxidant formation are currently being trialled to ascertain their potential ability to prevent disease progression. To determine the selectivity of such pharmacological treatments and to indentify new drug targets, a suitable method is required to detect target cysteine oxidation.

METHOD: Using a polyethylene glycol (PEG)-based alkylating agent the reversible oxidation of target proteins can be determined using a novel switch method. After reduction and specific labelling of reversibly oxidised thiols with a 'heavy' PEG-tag, samples are resolved on sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) gels, Western blotted and immunostained for protein(s) of interest. A mobility shift in a target protein following PEG-alkylation correlates with the reversible oxidative modification.

RESULTS

The oxidation of cAMP- and cGMP-dependent protein kinases was detected using the PEG-switch assay in Langendorff-perfused hearts after hydrogen peroxide was administered.

DISCUSSION: The PEG-switch assay is a fast effective semi-quantitative method for measuring target reversible cysteine oxidation in complex protein mixtures derived from tissue or cultured cells.

Для цитирования: Burgoyne Joseph Robert, Oviosu Olujimi, Eaton Philip. The PEG-switch assay: a fast semi-quantitative method to determine protein reversible cysteine oxidation.. Journal of pharmacological and toxicological methods. 2013. DOI: 10.1016/j.vascn.2013.07.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.