MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-022-17732-9

Медицинская библиотека · Scientific reports · 2022

Application of intentional facial nerve stimulation during cochlear implantation as an electrophysiological tool to estimate the intracochlear electrode position.

Herrmann David P, Müller-Graff Franz-Tassilo, Kaulitz Stefan, Cebulla Mario, Kurz Anja, Hagen Rudolf, Neun Tilmann, Rak Kristen

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

This proof of concept describes the use of evoked electromyographic (EMG) activation of the facial nerve for intraoperative monitoring of the electrode insertion during cochlear implantation (CI). Intraoperative EMG measurements from the facial nerve were conducted in nine patients undergoing CI implantation. Electric current pulses were emitted from contacts on the CI array during and immediately after electrode insertion. For control, the results of EMG measurements were compared to postoperative flat panel volume computed tomography scans with secondary reconstruction (fpVCTSECO). During insertion, the EMG response evoked by the electrical stimulation from the CI was growing with the stimulating contact approaching the facial nerve and declined with increasing distance. After full insertion, contacts on the apical half of the CI array stimulated higher EMG responses compared with those on the basal half. Comparison with postoperative imaging demonstrated that electrode contacts stimulating high EMG responses had the shortest distances to the facial nerve. It could be demonstrated that electrically evoked EMG activation of the facial nerve can be used to monitor the progress during CI electrode insertion and to control the intracochlear electrode position after full insertion.

Для цитирования: Herrmann David P, Müller-Graff Franz-Tassilo, Kaulitz Stefan, Cebulla Mario, Kurz Anja, Hagen Rudolf, Neun Tilmann, Rak Kristen. Application of intentional facial nerve stimulation during cochlear implantation as an electrophysiological tool to estimate the intracochlear electrode position.. Scientific reports. 2022. DOI: 10.1038/s41598-022-17732-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.