m+Medelevator.RU
← Поиск публикаций
JACC. Cardiovascular interventions · 2017

The Use of Embolic Protection Devices Is Associated With a Lower Stroke and Death Rate After Carotid Stenting.

СтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Knappich Christoph, Kuehnl Andreas, Tsantilas Pavlos, Schmid Sofie, Breitkreuz Thorben, Kallmayer Michael, Zimmermann Alexander, Eckstein Hans-Henning

Аннотация

OBJECTIVES: The aim of this study was to analyze the association between intraprocedural and periprocedural variables and in-hospital stroke or death rate after carotid artery stenting.

BACKGROUND: In Germany, all open surgical and endovascular procedures on the extracranial carotid artery must be documented in a statutory nationwide quality assurance database.

METHODS: A total of 13,086 carotid artery stenting procedures for asymptomatic (63.9%) or symptomatic carotid stenosis (mean age 69.7 years, 69.7% men) between 2009 and 2014 were recorded. The following variables were analyzed: stent design, stent material, neurophysiological monitoring, periprocedural antiplatelet medication, and use of an embolic protection device. The primary outcome was in-hospital stroke or death. Major stroke or death, any stroke, and death, all until discharge, were secondary outcomes. Adjusted relative risks (RRs) were assessed using multilevel multivariable regression analyses.

RESULTS: The primary outcome occurred in 2.4% of the population (1.7% in asymptomatic and 3.7% in symptomatic patients). The multivariable analysis showed an independent association between the use of an embolic protection device and lower in-hospital rates of stroke or death (adjusted RR: 0.65; 95% confidence interval [CI]: 0.50 to 0.85), major stroke or death (adjusted RR: 0.60; 95% CI: 0.43 to 0.84), and stroke (adjusted RR: 0.57; 95% CI: 0.43 to 0.77). Regarding the occurrence of in-hospital death, there was no significant association (adjusted RR: 0.78; 95% CI: 0.46 to 1.35). None of the outcomes was associated with stent design, stent material, neurophysiological monitoring, or antiplatelet medication.

CONCLUSIONS: The use of an embolic protection device was independently associated with lower in-hospital risk for stroke or death, major stroke or death, and stroke.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты