MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/tmi.2024.3405621

Медицинская библиотека · IEEE transactions on medical imaging · 2024

Do as Sonographers Think: Contrast-Enhanced Ultrasound for Thyroid Nodules Diagnosis via Microvascular Infiltrative Awareness.

Chen Fang, Han Haojie, Wan Peng, Chen Lingyu, Kong Wentao, Liao Hongen, Wen Baojie, Liu Chunrui, Zhang Daoqiang

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Dynamic contrast-enhanced ultrasound (CEUS) imaging can reflect the microvascular distribution and blood flow perfusion, thereby holding clinical significance in distinguishing between malignant and benign thyroid nodules. Notably, CEUS offers a meticulous visualization of the microvascular distribution surrounding the nodule, leading to an apparent increase in tumor size compared to gray-scale ultrasound (US). In the dual-image obtained, the lesion size enlarged from gray-scale US to CEUS, as the microvascular appeared to be continuously infiltrating the surrounding tissue. Although the infiltrative dilatation of microvasculature remains ambiguous, sonographers believe it may promote the diagnosis of thyroid nodules. We propose a deep learning model designed to emulate the diagnostic reasoning process employed by sonographers. This model integrates the observation of microvascular infiltration on dynamic CEUS, leveraging the additional insights provided by gray-scale US for enhanced diagnostic support. Specifically, temporal projection attention is implemented on time dimension of dynamic CEUS to represent the microvascular perfusion. Additionally, we employ a group of confidence maps with flexible Sigmoid Alpha Functions to aware and describe the infiltrative dilatation process. Moreover, a self-adaptive integration mechanism is introduced to dynamically integrate the assisted gray-scale US and the confidence maps of CEUS for individual patients, ensuring a trustworthy diagnosis of thyroid nodules. In this retrospective study, we collected a thyroid nodule dataset of 282 CEUS videos. The method achieves a superior diagnostic accuracy and sensitivity of 89.52% and 94.75%, respectively. These results suggest that imitating the diagnostic thinking of sonographers, encompassing dynamic microvascular perfusion and infiltrative expansion, proves beneficial for CEUS-based thyroid nodule diagnosis.

Для цитирования: Chen Fang, Han Haojie, Wan Peng, Chen Lingyu, Kong Wentao, Liao Hongen, Wen Baojie, Liu Chunrui, Zhang Daoqiang. Do as Sonographers Think: Contrast-Enhanced Ultrasound for Thyroid Nodules Diagnosis via Microvascular Infiltrative Awareness.. IEEE transactions on medical imaging. 2024. DOI: 10.1109/tmi.2024.3405621.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.