MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1213/ane.0000000000007295

Медицинская библиотека · Anesthesia and analgesia · 2024

Blood Pressure Estimation Using Explainable Deep-Learning Models Based on Photoplethysmography.

Perdereau Jade, Chamoux Thibaut, Gayat Etienne, Le Gall Arthur, Vallée Fabrice, Cartailler Jérôme, Joachim Jona

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Due to their invasiveness, arterial lines are not typically used in routine monitoring, despite their superior responsiveness in hemodynamic monitoring and detecting intraoperative hypotension. To address this issue, noninvasive, continuous arterial pressure monitoring is necessary. We developed a deep-learning model that reconstructs continuous mean arterial pressure (MAP) using the photoplethysmograhy (PPG) signal and compared it to the arterial line gold standard.

METHODS

We analyzed high-frequency PPG signals from 117 patients in neuroradiology and digestive surgery with a median of 2201 (interquartile range [IQR], 788-4775) measurements per patient. We compared models with different combinations of convolutional and recurrent layers using as inputs for our neural network high-frequency PPG and derived features including dicrotic notch relative amplitude, perfusion index, and heart rate. Mean absolute error (MAE) was used as performance metrics. Explainability of the deep-learning model was reconstructed with Grad-CAM, a visualization technique using saliency maps to highlight the parts of an input that are significant for a deep-learning model decision-making process.

RESULTS

An MAP baseline model, which consisted only of standard cuff measures, reached an MAE of 6.1 (± 14.5) mm Hg. In contrast, the deep-learning model achieved an MAE of 3.5 (± 4.4) mm Hg on the external test set (a 42.6% improvement). This model also achieved the narrowest confidence intervals and met international standards used within the community (grade A). The saliency map revealed that the deep-learning model primarily extracts information near the dicrotic notch region.

CONCLUSIONS

Our deep-learning model noninvasively estimates arterial pressure with high accuracy. This model may show potential as a decision-support tool in operating-room settings, particularly in scenarios where invasive blood pressure monitoring is unavailable.

Для цитирования: Perdereau Jade, Chamoux Thibaut, Gayat Etienne, Le Gall Arthur, Vallée Fabrice, Cartailler Jérôme, Joachim Jona. Blood Pressure Estimation Using Explainable Deep-Learning Models Based on Photoplethysmography.. Anesthesia and analgesia. 2024. DOI: 10.1213/ane.0000000000007295.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.