MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/01.brs.0000133646.40087.8b

Медицинская библиотека · Spine · 2004

Ultrastructural analysis of metallic debris and tissue reaction around spinal implants in patients with late operative site pain.

Senaran Hakan, Atilla Pergin, Kaymaz Figen, Acaroglu Emre, Surat Adil

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

STUDY

DESIGN

Cross-sectional ultrastructural analysis of metallic debris as well as the tissue reaction surrounding spinal implants in patients with late operative site pain.

OBJECTIVE

To clarify the cause of late operative site pain by the ultrastructural analysis of the byproducts of metallic corrosion as well as the surrounding soft tissues.

SUMMARY OF THE BACKGROUND DATA: Late operative site pain has been identified as the most frequent cause of implant removal. Allergic reaction to metal as well as low-grade infection has been suggested as probable mechanisms.

METHODS

Fourteen spinal implants were removed because of late operative site pain. Tissues obtained from different zones surrounding these implants were analyzed by light microscopy, transmission electron microscopy, and scanning electron microscopy along with electron dispersion radiograph analysis.

RESULTS

No signs of infection were present. Either one of the 2 types of connective tissue (dense or loose) were found to surround the implants. Macrophage counts were most abundant in zone II (around pedicular screws) when compared to other zones (zone I: around the rods; zone III: around the transverse rod connectors). In contrast, particulate debris was more abundant and larger in size in specimens from zone III. Two types of metallic debris were identified. The rusty appearing particles contained mostly iron (Fe), whereas the black appearing particles were rich in chromium (Cr).

CONCLUSION

This study produced useful information regarding the production and distribution of particulate metallic debris around stainless steel spinal implants.

Для цитирования: Senaran Hakan, Atilla Pergin, Kaymaz Figen, Acaroglu Emre, Surat Adil. Ultrastructural analysis of metallic debris and tissue reaction around spinal implants in patients with late operative site pain.. Spine. 2004. DOI: 10.1097/01.brs.0000133646.40087.8b.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.