Influence of vertebral column distraction on spinal cord volume: an experimental study in a goat model.

Qiu Feng, Yang Jin-Cheng, Ma Xiang-Yang, Xu Jun-Jie, Yang Qing-Lei, Zhou Xin, Xiao Yao-Sheng, Hu Hai-Sheng, Xia Li-Hui

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

INTRODUCTION

Spinal cord injury may be related to excessive distraction of the spinal cord during surgical correction of spinal deformities by vertebral column resection. This study aimed to investigate how vertebral column distraction influences spinal cord volume to establish the safe range in a goat model.

MATERIALS AND

METHODS

A vertebral column resection was performed on the tenth thoracic vertebra of 11 goats. The spinal cord was distracted until the somatosensory evoked potential signals were decreased to 50 % from baseline amplitude or were delayed by 10 % of the baseline peak latency. The osteotomy segment was stabilized with a PEEK mesh cage filled with bone graft, and the pedicle screws on the rods were then tightened in this position. Spinal cord volume was calculated using Mimics software, and T10 height, disk height, osteotomy segment height, and spinal segment height were measured using the MRI image workstation.

RESULTS

Three goats were excluded, and data obtained from the eight remaining goats were analyzed. The safe limit of distraction distance was 11.8 ± 3.65 mm, and the distraction distance was strongly correlated with the difference between the pre- and postoperative measurements (d value) of spinal cord volume per 1 mm of osteotomy segment height (r = -0.952, p < 0.001), but was not correlated with T10 body height (r = 0.16, p = 0.71), spinal segment height (r = 0.29, p = 0.49), disk height (r = -0.12, p = 0.98), or the d value (pre-post) of spinal cord volume per 1 mm of spinal segment height (r = 0.45, p = 0.26). The mean d value (pre-post) of spinal cord volume per 1 mm of osteotomy segment height was 10.05 ± 0.02 mm(3) (range 10.02-10.08 mm(3)).

CONCLUSION

The maximum change in spinal cord volume per 1-mm change in height was in the osteotomy segment, and its safe limit was 10.05 ± 0.02 mm(3). The safe limit of spinal cord distraction can be calculated using the spinal cord volume per unit 1-mm change in height.

Для цитирования: Qiu Feng, Yang Jin-Cheng, Ma Xiang-Yang, Xu Jun-Jie, Yang Qing-Lei, Zhou Xin, Xiao Yao-Sheng, Hu Hai-Sheng, Xia Li-Hui. Influence of vertebral column distraction on spinal cord volume: an experimental study in a goat model.. Archives of orthopaedic and trauma surgery. 2015. DOI: 10.1007/s00402-015-2264-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.