MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clinbiochem.2008.06.010

Медицинская библиотека · Clinical biochemistry · 2008

Specific, rapid, and sensitive enzymatic measurement of sphingomyelin, phosphatidylcholine and lysophosphatidylcholine in serum and lipid extracts.

Hidaka Hiroya, Yamauchi Kazuyoshi, Ohta Hiroyashi, Akamatsu Taiji, Honda Takayuki, Katsuyama Tsutomu

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

Human serum sphingomyelin (SM) and phosphatidylcholine (PC) play important roles in the development of atherosclerosis. However, there are no rapid and sensitive methods for SM and PC measurement. The present report describes a novel enzymatic method for measuring SM, PC and lysophosphatidylcholine (lyso-PC) levels in plasma and lipid extracts.

DESIGN AND

METHODS

The total choline-containing phospholipids (total PL), SM and PC were measured using a two-reagent system involving specific enzymes for choline-based phospholipids. The procedure was performed using either microplate or automatic analyzer technology. The concentration of lyso-PC was calculated by subtracting the concentration of SM plus PC from the total PL concentration.

RESULTS

Assay results showed linear correlations between sample concentration and absorbance. The within-run and between-run coefficients of variation for PC, SM, and lyso-PC concentrations were 2.0-4.4% for the microplate analyzer and 0.9-2.9% for the automatic analyzer. Analysis of normal human serum showed that the total PL concentration strongly correlated with the SM plus PC concentration (r=0.9850). There were moderate correlations between serum PC and SM levels (r=0.6228) and between serum PC and lyso-PC levels (r=0.7806). SM, PC, and lyso-PC levels in normal human serum (n=50) were 0.54+/-0.07, 1.99+/-0.22 and 0.60+/-0.15 mmol/L, respectively.

CONCLUSION

The present enzymatic method allowed for rapid, simple, and accurate measurement of SM, PC, and lyso-PC levels in lipid extracts and in serum. The method is suitable for both microplate and automatic analyzer assays.

Для цитирования: Hidaka Hiroya, Yamauchi Kazuyoshi, Ohta Hiroyashi, Akamatsu Taiji, Honda Takayuki, Katsuyama Tsutomu. Specific, rapid, and sensitive enzymatic measurement of sphingomyelin, phosphatidylcholine and lysophosphatidylcholine in serum and lipid extracts.. Clinical biochemistry. 2008. DOI: 10.1016/j.clinbiochem.2008.06.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.