MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1365-2257.1990.tb00037.x

Медицинская библиотека · Clinical and laboratory haematology · 1990

Howell-Jolly body counting as a measure of splenic function. A reassessment.

Corazza G R, Ginaldi L, Zoli G, Frisoni M, Lalli G, Gasbarrini G, Quaglino D

СтатьяПеревод в очереди

Аннотация

Non-surgical and surgical asplenia predisposes to fatal infections; therefore, simple, non-invasive and repeatable tests for assessing splenic function are required, even in non-specialized medical institutions. Howell-Jolly bodies are the most characteristic peripheral blood abnormality after splenectomy, but their counting is not considered a reliable measure of splenic function. In this study, in a group of splenectomized subjects and of patients with non-surgical hyposplenism, we have compared counting of Howell-Jolly bodies, stained by both the May-Grünwald/Giemsa method and the Feulgen reaction, with pitted cell counting which is considered a reliable technique for the assessment of splenic hypofunction. A significant correlation has been found between Howell-Jolly body counts, stained by either technique, and pitted cell counts (P less than 0.0001). Through Howell-Jolly bodies were never detectable when pitted cell counts fell between 4 and 8%, values consistent with a very mild splenic hypofunction, for pitted cell counts above 8% their increase was always associated with increasing Howell-Jolly body counts. These data suggest that, although pitted cell counting represents a more sensitive method for evaluating splenic function, Howell-Jolly body counting may still be regarded as a simple and reliable technique for identifying and monitoring those cases associated with a real risk of overwhelming infections.

Для цитирования: Corazza G R, Ginaldi L, Zoli G, Frisoni M, Lalli G, Gasbarrini G, Quaglino D. Howell-Jolly body counting as a measure of splenic function. A reassessment.. Clinical and laboratory haematology. 1990. DOI: 10.1111/j.1365-2257.1990.tb00037.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.