MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5740/jaoacint.10-263

Медицинская библиотека · Journal of AOAC International · 2013

Development and validation of an analytical method for quantification of arsenic and antimony in liposomes using inductively coupled plasma-optical emission spectrometry.

Reis Priscila G, Abreu Adriana T, Guimarães Andrea G, Teixeira Mônica C, de Souza Jacqueline, Silva-Barcellos Neila M

СтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод пока не подготовлен

Аннотация

Arsenic and antimony compounds are used to treat endemic diseases, such as cancer, leishmaniasis, and schistosomiasis, in spite of their toxicity. Several studies seeking the development and characterization of nanocarrier systems such as liposomes are being carried out with the aim of developing new drug delivery systems and minimizing the toxicity of these drugs. However, the lack of reference methods to quantify these semimetals within a liposomal matrix hinders the QC of these formulations. Therefore, the validation of an analytical method for arsenic and antimony quantification in liposomal matrix by inductively coupled plasma-optical emission spectrometry is presented here. The linearity, specificity, LOD, LOQ, accuracy, and precision were determined according to the International Conference on Harmonization norms and the Brazilian Health Surveillance Agency (Resolution 899). The LOD values were 0.02 and 0.06 mg/L for antimony and arsenic, respectively. The LOQ for both was 3.0 mg/L, with an adequate accuracy within 98.26 and 101.32% for different levels of antimony and 99.98 and 100.36% for arsenic. Precision (CV) was lower than 5.0%. The developed and validated method was shown to be reproducible for quantification of arsenic and antimony in liposome pharmaceutical dosage forms.

Для цитирования: Reis Priscila G, Abreu Adriana T, Guimarães Andrea G, Teixeira Mônica C, de Souza Jacqueline, Silva-Barcellos Neila M. Development and validation of an analytical method for quantification of arsenic and antimony in liposomes using inductively coupled plasma-optical emission spectrometry.. Journal of AOAC International. 2013. DOI: 10.5740/jaoacint.10-263.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.