Optometry and vision science : official publication of the American Academy of Optometry · 2016
Anterior Segment Biometry Changes with Cycloplegia in Myopic Adults.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Chang Shu-Wen, Lo Andy Y, Su Po-Fang
Аннотация
PURPOSE: To determine the effect of cycloplegia on corneal thickness, corneal curvature, anterior chamber depth (ACD), angle-to-angle (ATA) and white-to-white (WTW) distances, and axial length (AL).
METHODS: Changes in corneal thickness, corneal curvature, ACD, ATA and WTW distances, and AL with and without cycloplegia were analyzed in 31 eyes of 31 young myopic adults, aged 26.4 ± 3.0 years. Pentacam was used to measure the corneal thickness, corneal volume, and corneal curvatures. Visante optical coherent tomography (OCT) measured corneal thickness, ATA distance, ACD, and pupil size. The AL and WTW distance were measured using IOLMaster.
RESULTS: Cycloplegia induced significant flattening of corneal curvatures (p = 0.019, 0.001, and 0.003 for anterior sagittal, posterior tangential, and posterior sagittal curvatures, respectively). The difference in the posterior corneal curvature was greater in corneas with steeper posterior curvatures. Cycloplegia also induced significant deepening of ACD (0.08 ± 0.06, p < 0.001) and widening of both WTW (0.42 ± 0.43, p < 0.001) and ATA (0.08 ± 0.17, p = 0.015) distances. The cycloplegia-related increase in the ATA distance correlated negatively with AL (r = -0.361, p = 0.046), whereas the cycloplegia-related increase in WTW distance correlated weakly with the increase in ACD (r = 0.347, p = 0.056) but not with AL. The AL did not change with cycloplegia. Pentacam measured a slightly thicker cornea than OCT (p = 0.002). Both Pentacam and OCT detected a significant increase in corneal thickness of 4 μm, which could be attributed to reflex tearing, after cycloplegia.
CONCLUSIONS: Cycloplegia resulted in deeper ACD, greater ATA distance, and flatter corneal curvatures. Surgeons should be aware of these cycloplegia-related alterations for more accurate phakic/functional intraocular lens selection and better refraction results.
METHODS: Changes in corneal thickness, corneal curvature, ACD, ATA and WTW distances, and AL with and without cycloplegia were analyzed in 31 eyes of 31 young myopic adults, aged 26.4 ± 3.0 years. Pentacam was used to measure the corneal thickness, corneal volume, and corneal curvatures. Visante optical coherent tomography (OCT) measured corneal thickness, ATA distance, ACD, and pupil size. The AL and WTW distance were measured using IOLMaster.
RESULTS: Cycloplegia induced significant flattening of corneal curvatures (p = 0.019, 0.001, and 0.003 for anterior sagittal, posterior tangential, and posterior sagittal curvatures, respectively). The difference in the posterior corneal curvature was greater in corneas with steeper posterior curvatures. Cycloplegia also induced significant deepening of ACD (0.08 ± 0.06, p < 0.001) and widening of both WTW (0.42 ± 0.43, p < 0.001) and ATA (0.08 ± 0.17, p = 0.015) distances. The cycloplegia-related increase in the ATA distance correlated negatively with AL (r = -0.361, p = 0.046), whereas the cycloplegia-related increase in WTW distance correlated weakly with the increase in ACD (r = 0.347, p = 0.056) but not with AL. The AL did not change with cycloplegia. Pentacam measured a slightly thicker cornea than OCT (p = 0.002). Both Pentacam and OCT detected a significant increase in corneal thickness of 4 μm, which could be attributed to reflex tearing, after cycloplegia.
CONCLUSIONS: Cycloplegia resulted in deeper ACD, greater ATA distance, and flatter corneal curvatures. Surgeons should be aware of these cycloplegia-related alterations for more accurate phakic/functional intraocular lens selection and better refraction results.