DOI 10.1007/s10006-020-00911-1
Puncture points related to the tragal-lateral canthus line in conventional temporomandibular joint arthrocentesis: are they accurate? A cadaver study.
Аннотация
PURPOSE: To evaluate the technical success of conventional TMJ arthrocentesis in cadavers, using the tragal-lateral canthus line as an anatomical reference for the puncture points.
METHODS
Ten formalin-treated and 8 fresh cadavers were submitted to the arthrocentesis. A point located 10 mm anteriorly and 2 mm inferiorly to the beginning of the tragal-lateral canthus line (A) and another point 20 mm anteriorly and 10 mm inferiorly (B) were demarked on the cadavers' skin. Following, 1 mL of methylene blue solution was injected through the needle at point A, and then another needle was placed at point B. Saline solution was injected through the first needle, identifying a free flow of bluish solution.
RESULTS
Concerning the formalin-treated cadavers, TMJ arthrocentesis was not successfully performed in any case (0%). In the fresh cadavers, the procedure was properly conducted bilaterally in only one case (12.5%) and unilaterally in 3 cases (37.5%), 2 on the left side (25.0%) and one on the right (12.5%).
CONCLUSION
The traditional points related to the tragal-lateral canthus line seemed not to be accurate references for the insertion of the needles in conventional TMJ arthrocentesis when 1 mL of solution is used initially and the maximum mouth opening is not achieved.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.