Glycemic control, including Time in Tight Range (TITR) evaluation, in children with type 1 diabetes treated with the MiniMed 780G system: a 3-year prospective, observational, two-center study.

Tarasiewicz Mateusz, Bartnikowska Wiktoria, Chobot Agata, Bielawska Anna, Zając Agnieszka, Polańska Joanna, Jarosz-Chobot Przemysława, Seget Sebastian

СтатьяНаблюдательное исследованиеМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

The MiniMed 780G was the first commercially available automated insulin delivery (AID) system in Poland. The aim of this study was to analyze glycemic management in children with type 1 diabetes (T1D) after three years of using the system.

MATERIALS AND

METHODS

The data included anthropometric measurements, information from insulin pumps, and continuous glucose monitoring (CGM) from fifty children with T1D (mean age: 9.9 ± 2.4 years; T1D duration at baseline: 3.9 ± 2.56 years) using the MiniMed 780G. The data were collected at AID initiation, 12 and 36 months after starting its use.

RESULTS

Coefficient of variation (CV) and body mass index (BMI) z-scores at baseline and after 3 years were comparable (p > 0.05). TITR firstly increased after the AID system implementation with the peak value after 6 months (60.82% ± 9.34), then the values decreased to 56.50%± 10.78% after 3 years (p<0.001). Time in range (70-180 mg/dL) decreased after 3 years of observation compared to peak values at 6 and 12 months (77.74% ± 7.65% versus 81.16% ± 7.83% and 80.40% ± 8.25%, respectively, p<0.005. The percentage of auto-correction in total daily insulin dose increased significantly (11.24% ± 6.08% 2 weeks of AID system usage vs. 16.34% ± 6.69% after 3 years; p < 0.001).

CONCLUSIONS

Despite a slight deterioration after 3 years, optimal glycemic management was maintained throughout the observation period. GCM metrics remained within recommended values in early adolescence, most likely due to auto-correction boluses.

Для цитирования: Tarasiewicz Mateusz, Bartnikowska Wiktoria, Chobot Agata, Bielawska Anna, Zając Agnieszka, Polańska Joanna, Jarosz-Chobot Przemysława, Seget Sebastian. Glycemic control, including Time in Tight Range (TITR) evaluation, in children with type 1 diabetes treated with the MiniMed 780G system: a 3-year prospective, observational, two-center study.. Frontiers in endocrinology. 2026. DOI: 10.3389/fendo.2026.1750164.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.