MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1148/radiology.204.2.9240535

Медицинская библиотека · Radiology · 1997

Trigeminal neuralgia: comparison of two MR imaging techniques in the demonstration of neurovascular contact.

Majoie C B, Hulsmans F J, Verbeeten B, Castelijns J A, van Beek E J, Valk J, Bosch D A

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare two magnetic resonance (MR) imaging techniques for demonstration of vascular contact with the trigeminal nerve.

MATERIALS AND

METHODS

Thirteen patients with unilateral trigeminal neuralgia and 50 control subjects underwent three-dimensional fast inflow with steady-state precession (FISP) and contrast material-enhanced magnetization-prepared rapid acquisition gradient-echo (MP-RAGE) MR imaging. The images were independently reviewed by two neuroradiologists, who were blinded to the clinical details. Six of the 13 patients underwent surgery.

RESULTS

Vascular contact with the trigeminal nerve at the root entry zone was seen on FISP images in 10 of 13 (77%) symptomatic nerves and in eight of 113 (7%) asymptomatic nerves (P < .001). MP-RAGE and FISP images demonstrated arterial contacts equally well. MP-RAGE images demonstrated one additional venous contact at the root entry zone in a patient with ipsilateral trigeminal neuralgia. Interobserver agreement was good for both FISP (kappa = 0.69) and MP-RAGE (kappa = 0.78) images. The presence of vascular contact at the root entry zone, seen on preoperative MR images, was confirmed in all six patients who underwent surgery.

CONCLUSION

Both FISP and MP-RAGE MR imaging are useful in demonstrating vascular contact with the trigeminal nerve at the root entry zone in patients with trigeminal neuralgia.

Для цитирования: Majoie C B, Hulsmans F J, Verbeeten B, Castelijns J A, van Beek E J, Valk J, Bosch D A. Trigeminal neuralgia: comparison of two MR imaging techniques in the demonstration of neurovascular contact.. Radiology. 1997. DOI: 10.1148/radiology.204.2.9240535.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.