Partial nephrectomy using the Nd:YAG laser: a comparison of the 1.06 mu and 1.32 mu lasers employing different delivery systems.

Johnson D E, Wishnow K I, von Eschenbach A C, Grignon D, Ayala A G

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

A comparative study of the 1.06 mu and the 1.32 mu Nd:YAG laser using a variety of delivery systems (focusing handpiece, freehand GI quartz fiber, or frosted laser scalpel) was undertaken to determine the usefulness of these modalities in performing partial nephrectomies in dogs. Variables evaluated included total operative time, total joules expended, estimated amount of blood loss, and extent of renal tissue damage. The contact laser scalpel provided the greatest precision and speed, but no hemostasis, and is therefore inappropriate for parenchymal renal surgery. Evaluation of the other delivery systems showed no discernible differences in the extent of renal damage that could be attributed to either wavelength or wattage used. The usual depth of acute renal damage ranged from 1.0 mm to 1.8 mm when the tissue was fixed immediately after completing the polar nephrectomy, but the damage had extended to 3.0 mm when tissue was examined after 6 weeks. No consistent differences in extent of cellular damage could be demonstrated between the renal cortex and medulla. The lens system inherent in the focusing handpiece limited the total power (60 watts) that could be employed and surgery proceeded at a slower pace and required a greater expenditure of energy. Likewise, the maximal power that could be applied using the 1.32 mu laser was 25 watts and surgery also proceeded at a slower pace.(ABSTRACT TRUNCATED AT 250 WORDS)

Для цитирования: Johnson D E, Wishnow K I, von Eschenbach A C, Grignon D, Ayala A G. Partial nephrectomy using the Nd:YAG laser: a comparison of the 1.06 mu and 1.32 mu lasers employing different delivery systems.. Lasers in surgery and medicine. 1988. DOI: 10.1002/lsm.1900080304.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.