Sensitivity and specificity of decreased CSF asialotransferrin for eIF2B-related disorder.

Сравнительное исследованиеСтатьяПоддержка NIH: внешняя программаResearch Support, N.I.H., IntramuralПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Vanderver A, Hathout Y, Maletkovic J, Gordon E S, Mintz M, Timmons M, Hoffman E P, Horzinski L, Niel F, Fogli A, Boespflug-Tanguy O, Schiffmann R

Аннотация

OBJECTIVE: This is a study estimating diagnostic accuracy of CSF asialotransferrin to transferrin ratio measurement in eIF2B related disorders by using clinical evaluation and EIF2B mutation analysis as the reference standard. eIF2B-related disorder is a relatively common leukodystrophy with broad phenotypic variation that is caused by mutations in any of the five EIF2B genes. There is a need for a simple and clinically valid screening tool for physicians evaluating patients with an unclassified leukodystrophy.

METHODS: CSF two-dimensional gel (2DG) electrophoresis analyses to measure asialotransferrin to transferrin ratios were performed in 60 subjects including 6 patients with documented EIF2B gene mutations, patients with other types of leukodystrophy, and patients with no leukodystrophy.

RESULTS: All six patients with mutation proven eIF2B-related disease showed low to nearly undetectable amounts of asialotransferrin in their CSF when compared to 54 unaffected controls by CSF 2DG analyses in this study. eIF2B-like patients, with clinically similar presentations but no mutations in EIF2B1-5, were distinguished from patients with mutations in EIF2B1-5 by this biomarker. Patients with mutations in EIF2B1-5 had asialotransferrin/transferrin ratio levels significantly different from the group as a whole (p < 0.001). Using 8% asialotransferrin/transferrin ratio as a cutoff, this biomarker has a 100% sensitivity (95% CI = 52-100%) and 94% specificity (95% CI = 84-99%).

CONCLUSION: Decreased asialotransferrin/transferrin ratio in the CSF of patients with eIF2B-related disorder is highly sensitive and specific. This rapid (<48 hours) and inexpensive diagnostic tool for eIF2B-related disorders has the potential to identify patients with likely eIF2B-related disorder for mutation analysis.