Robotic right colectomy using the Da Vinci Single-Site® platform: case report.

Morelli Luca, Guadagni Simone, Caprili Giovanni, Di Candio Giulio, Boggi Ugo, Mosca Franco

Клинический случайСтатьяОбзорПеревод пока не подготовлен

Аннотация

BACKGROUND

While single-port laparoscopy for abdominal surgery is technically challenging, the Da Vinci Single-Site® robotic surgery platform may help to overcome some of the difficulties of this rapidly evolving technique. The authors of this article present a case of single-incision, robotic right colectomy using this device.

METHODS

A 74-year-old female with malignant polyp of caecum was operated on with a single-site approach using the Da Vinci Single-Site® robotic surgery device. Resection and anastomosis were performed extra-corporeally after undocking the robot.

RESULTS

The procedure was successfully completed in 200 min. No surgical complications occurred during the intervention and the post-operative stay and no conversion to laparotomy or additional trocars were required.

CONCLUSIONS

To the best of our knowledge, this is the first case of right colectomy using the Da Vinci Single-Site® robotic surgery platform to be reported. The procedure is feasible and safe and its main advantages are restoration of triangulation and reduced instrument clashes.

Для цитирования: Morelli Luca, Guadagni Simone, Caprili Giovanni, Di Candio Giulio, Boggi Ugo, Mosca Franco. Robotic right colectomy using the Da Vinci Single-Site® platform: case report.. The international journal of medical robotics + computer assisted surgery : MRCAS. 2013. DOI: 10.1002/rcs.1488.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.