Usefulness of contrast-enhanced ultrasound using perfluorobutanecontaining microbubbles as a planning for percutaneous biopsies of focal hepatic lesions: a prospective feasibility study.
Аннотация
AIMS: To determine whether contrast-enhanced US using perfluorobutane-containing microbubbles (SEUS) would be helpful for planning a hepatic biopsy.
MATERIAL AND
METHODS
This prospective study included 40 patients who planned to undergo hepatic biopsy for focal hepatic lesions. All patients underwent B-mode US followed by SEUS. The radiologist evaluated the number of detected lesions, presence of necrosis, conspicuity of target lesion and technical feasibility using 4-point scale. Technical failure and occurrence of change of the target were also assessed. Computer tomography (CT) or magnetic resonance (MR) images were the reference techniques.
RESULTS
The mean number of lesions detected on CT and MR images was 6.5±8.4. In 20 (50%) of 40 patients, more focal lesions were detected on SEUS. Targeted lesion was changed in sixpatients (15%) on SEUS. Mean number of detected lesions on SEUS was significantly higher comparing with B-US (5.1±6.2 vs. 2.8±3.8, p<0.001). Conspicuity of the targeted lesion was improved in 67.5% (27 of 40) on SEUS and significantly more visualized than B-US (3.6±0.8 vs. 2.8±0.9, p<0.001). In 7 more patients the necrosis within the lesion was visualized (17.5%) using SEUS. The technical feasibility on SEUS was significantly higher than B-US (2.3±1.0 vs. 3.3±0.9, p<0.001). Technical failure was observed in only one patient (2.5%).
CONCLUSIONS
SEUS is a helpful technique for planning the hepatic biopsyin terms of detection, improving lesion conspicuity, tumor viable portion assessment and consequently higher operator confidence, compared with B-US.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.