DOI 10.3233/ch-151961

Медицинская библиотека · Clinical hemorheology and microcirculation · 2016

Measurement of platelet aggregation functions using whole blood migration ratio in a microfluidic chip.

Seo Hong Seog, Choi Sung Hyuk, Han Miran, Kim Kyeong Ah, Cho Chi Hyun, An Seong Soo A, Lim Chae Seung, Shin Sehyun

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Platelets play a major role in maintaining endothelial integrity and hemostasis. Of the various soluble agonists, ADP is an important in vivo stimulus for inducing platelet aggregation. In this study, a simple, rapid, and affordable method was designed for testing bleeding time (BT) and platelet aggregation with a two-channel microfluidic chip. Whole blood migration ratio (MR) from a microchip system was evaluated in comparison to the closure time (CT) from PFA-100 assays (Siemens, Germany) and CD62P expression on platelets. To induce platelet aggregation, a combination of collagen (1.84 mg/ml) and ADP (37.5 mg/ml) were used as agonists. After adding the agonists to samples, whole blood MR from the microchip system was measured. The outcome of the assessment depended on reaction time and agonist concentration. MR of whole blood from the microchip system was significantly correlated with CT from PFA-100 (r = 0.61, p <  0.05, n = 60). In addition, MR was negatively correlated with CD62P expression (r =-0.95, p <  0.05, n = 60). These results suggest that the measurement of MR using agonists is an easy, simple and efficient method for monitoring platelet aggregation in normal and ADP-receptors defective samples, along with the BT test. Thus, usage of the current microfluidic method could expand to diverse applications, including efficacy assessments in platelet therapy.

Для цитирования: Seo Hong Seog, Choi Sung Hyuk, Han Miran, Kim Kyeong Ah, Cho Chi Hyun, An Seong Soo A, Lim Chae Seung, Shin Sehyun. Measurement of platelet aggregation functions using whole blood migration ratio in a microfluidic chip.. Clinical hemorheology and microcirculation. 2016. DOI: 10.3233/ch-151961.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.