MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Clinical hemorheology and microcirculation · 2008

Intraarterial gadolinium-enhanced magnetic resonance angiography of the renal arteries in humans: feasibility, contrast agent reduction, and accuracy for detection of stenoses.

Zorger N, Jung E M, Hamer O W, Paetzel C, Schreyer A, Seitz J, Stehr A, Steinbauer M, Feuerbach S, Herold T

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Feasibility of intraarterial MR angiography of the renal arteries and comparison of the accuracy of intraarterial MR angiography with selective intraarterial digital subtraction angiography (DSA) for detection of stenoses.

MATERIALS AND

METHODS

Ten consecutive patients (mean, 68 years) with suspected renal artery stenosis underwent a digital subtraction angiography and an intraarterial gadolinium-enhanced MR angiography, performed on a 1.5-T system. For intraarterial MR angiography 60 ml diluted contrast agent (10 ml gadodiamide in 50 ml 0.9% saline solution) was injected through a conventional angiography catheter placed in the suprarenal abdominal aorta using a flow rate of 3.5 ml/s. A three-dimensional (3D) gradient-echo sequence was performed. Differences in the quantitative measurement of stenoses of lesions between DSA and intraarterial MR angiography were evaluated by three observers. Overall impression of the intraarterial MR angiography was documented on a four-point scale (1 = excellent to 4 = poor). Interobserver variability was calculated.

RESULTS

Intraarterial MR angiography of the renal arteries was feasible in all patients (100%) with a mean overall impression of all images of 1.8 (SD: 0.71). One of 9 accessory renal arteries was not visualized with intraarterial MR angiography. The overall sensitivity/specificity for detection of significant stenoses (>or=50% stenosis) were 83%/87%. Interobserver variability of intraarterial MR angiography ranged between fair and substantial (0.359-0.622).

CONCLUSION

Intraarterial MR angiography of the renal arteries in humans is feasible and has an acceptable sensitivity in detecting stenoses using injections of diluted contrast agent at concentrations as low as 17%.

Для цитирования: Zorger N, Jung E M, Hamer O W, Paetzel C, Schreyer A, Seitz J, Stehr A, Steinbauer M, Feuerbach S, Herold T. Intraarterial gadolinium-enhanced magnetic resonance angiography of the renal arteries in humans: feasibility, contrast agent reduction, and accuracy for detection of stenoses.. Clinical hemorheology and microcirculation. 2008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.