Fornusek C, Gwinn T H, Heard R
Аннотация
STUDY DESIGN: Prospective experimental.
OBJECTIVES: To compare the cardiorespiratory responses with electrical stimulation (ES) producing either dynamic leg cycling or intermittent isometric leg contractions using the same ES protocol.
SETTING: Sydney, Australia.
METHODS: Eight paraplegics (T4-T11) performed ES exercise sessions on two separate days. On day 1, cardiorespiratory responses were measured during 5 min of rest followed by 35 min of cycling, and finally 15 min of intermittent isometric exercise using the same ES parameters. On the second day, after 5 min of rest, 35 min of isometric exercise was performed followed by 15 min of cycling.
RESULTS: There were no significant differences during the first 35 min of exercise on each day comparing the two modes of exercise for average rate of oxygen consumption (cycling, 534±128 ml min(-1); isometric 558±146 ml min(-1); P=0.451), the average heart rate (cycling, 93±15 b.p.m.; isometric 95±17 b.p.m.; P=0.264) or minute ventilation (cycling, 23.0±6.5 l min(-1); isometric 23.8±6.7 l min(-1); P=0.655). In addition, there were no significant differences between exercise modes for any peak cardiorespiratory values recorded during the initial 35 min of exercise or the following 15 min crossover exercise phase.
CONCLUSION: The current data found that intermittent ES leg isometric exercise elicited a similar cardiorespiratory response compared with functional ES leg cycling, suggesting it should be investigated as a viable alternative intervention for increasing whole body metabolic rate during sustained exercise training sessions for individuals with paralyzed muscles.
OBJECTIVES: To compare the cardiorespiratory responses with electrical stimulation (ES) producing either dynamic leg cycling or intermittent isometric leg contractions using the same ES protocol.
SETTING: Sydney, Australia.
METHODS: Eight paraplegics (T4-T11) performed ES exercise sessions on two separate days. On day 1, cardiorespiratory responses were measured during 5 min of rest followed by 35 min of cycling, and finally 15 min of intermittent isometric exercise using the same ES parameters. On the second day, after 5 min of rest, 35 min of isometric exercise was performed followed by 15 min of cycling.
RESULTS: There were no significant differences during the first 35 min of exercise on each day comparing the two modes of exercise for average rate of oxygen consumption (cycling, 534±128 ml min(-1); isometric 558±146 ml min(-1); P=0.451), the average heart rate (cycling, 93±15 b.p.m.; isometric 95±17 b.p.m.; P=0.264) or minute ventilation (cycling, 23.0±6.5 l min(-1); isometric 23.8±6.7 l min(-1); P=0.655). In addition, there were no significant differences between exercise modes for any peak cardiorespiratory values recorded during the initial 35 min of exercise or the following 15 min crossover exercise phase.
CONCLUSION: The current data found that intermittent ES leg isometric exercise elicited a similar cardiorespiratory response compared with functional ES leg cycling, suggesting it should be investigated as a viable alternative intervention for increasing whole body metabolic rate during sustained exercise training sessions for individuals with paralyzed muscles.