Association between scanning frequency of flash glucose monitoring and continuous glucose monitoring-derived glycemic makers in children and adolescents with type 1 diabetes.

Suzuki Junichi, Urakami Tatsuhiko, Yoshida Kei, Kuwabara Remi, Mine Yusuke, Aoki Masako, Morioka Ichiro

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

We assessed the association between scanning frequency of flash glucose monitoring (FGM) and continuous glucose monitoring (CGM)-derived glycemic markers in children and adolescents with type 1 diabetes.

METHODS

Subjects consisted of 85 children and adolescents with type 1 diabetes using FGM. We assessed the association between scanning frequencies of FGM- and CGM-derived metrics: Time in range (TIR) (70-180 mg/dL), time below range (TBR) (<70 mg/dL), time above range (>180 mg/dL), and other glycemic markers - laboratory-measured HbA1c and CGM-estimated glucose and HbA1c (eA1c) levels in the subjects.

RESULTS

The mean number of scans was 11.5 ± 3.5 (5-20) times per day, and scanning was most frequently conducted during a period of 18-24 h. Scanning frequency showed significant positive correlation with TIR (r = 0.719, P < 0.0001) and inverse correlation with time above range (r = -0.743, P < 0.0001), but did not correlate with TBR. There were also significant inverse correlations between scanning frequency and glucose, HbA1c, and eA1c levels (r = -0.765, -0.815, and -0.793, respectively, P < 0.0001).

CONCLUSIONS

Frequent glucose testing with FGM decreased hyperglycemia with increased TIR, but did not reduce TBR. Coping with a rapid fall of glucose and unexpected hypoglycemia with more advanced technology might contribute to a reduction in TBR.

Для цитирования: Suzuki Junichi, Urakami Tatsuhiko, Yoshida Kei, Kuwabara Remi, Mine Yusuke, Aoki Masako, Morioka Ichiro. Association between scanning frequency of flash glucose monitoring and continuous glucose monitoring-derived glycemic makers in children and adolescents with type 1 diabetes.. Pediatrics international : official journal of the Japan Pediatric Society. 2021. DOI: 10.1111/ped.14412.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.