MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.nephro.2022.10.001

Медицинская библиотека · Nephrologie & therapeutique · 2022

Automated complete blood counter, urine analyzer and urine dipstick test results are correlated with thoma cell counting chamber counts in the diagnosis of dialysis related peritonitis in children.

Keskin Gözmen Şükran, Serdaroğlu Erkin, Dinçel Nida, Erturgut Pınar, Başaran Cemaliye, Devrim Fatma, Pehlivan Zorlu Betül, Dur Özlem, Deniz Kara Orhan, Bekiroğlu Yilmaz Ebru

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Peritoneal dialysis is the treatment of choice for end-stage renal disease. Peritoneal dialysis related peritonitis is of great importance for patient and technical survival. The aim of our study was to evaluate the accuracy and the correlation between the three methods (complete blood count, urinalysis device, urine dipstick test) and with the reference manual method (Thoma Cell Counter Chamber).

MATERIALS AND

METHODS

We retrospectively analyzed 167 peritoneal fluid samples taken from 25 patients receiving peritoneal dialysis treatment. Leukocyte counts were evaluated with Thoma Cell Counter Chamber, complete blood count, urinalysis device and urine dipstick test.

RESULTS

There was a significant positive correlation between Thoma Cell Counter Chamber and complete blood count results (Spearman's rho=0.70), between Thoma Cell Counter Chamber and urinalysis device (Spearman's rho=0.73), and between Thoma Cell Counter Chamber and urine dipstick test (Spearman's rho=0.71). Area under curve for complete blood count, urinalysis device and urine dipstick test were 0.93, 0.94 and 0.89 respectively, indicating good accuracy. Sensitivity and specificity were 89.7% and 86.7% in the complete blood count analysis (associated criterion: 130 cells/mm3). Sensitivity and specificity were 89.7% and 86.7% in the urinalysis device (associated criterion: 10 cells/HPF). Sensitivity and specificity were 79.6% and 91.4% when in the urine dipstick test analysis (associated criterion: +1 positivity). The Bland-Altman plot showed good agreement.

CONCLUSION

Automatic complete blood count and urinalysis devices have good correlation and agreement with manual method in the diagnosis of peritonitis in the pediatric age group. Urine dipstick test in the home setting can be useful for screening patients with suspected peritonitis.

Для цитирования: Keskin Gözmen Şükran, Serdaroğlu Erkin, Dinçel Nida, Erturgut Pınar, Başaran Cemaliye, Devrim Fatma, Pehlivan Zorlu Betül, Dur Özlem, Deniz Kara Orhan, Bekiroğlu Yilmaz Ebru. Automated complete blood counter, urine analyzer and urine dipstick test results are correlated with thoma cell counting chamber counts in the diagnosis of dialysis related peritonitis in children.. Nephrologie & therapeutique. 2022. DOI: 10.1016/j.nephro.2022.10.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.