MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijrobp.2024.07.2318

Медицинская библиотека · International journal of radiation oncology, biology, physics · 2024

Extended nnU-Net for Brain Metastasis Detection and Segmentation in Contrast-Enhanced Magnetic Resonance Imaging With a Large Multi-Institutional Data Set.

Yoo Youngjin, Gibson Eli, Zhao Gengyan, Re Thomas J, Parmar Hemant, Das Jyotipriya, Wang Hesheng, Kim Michelle M, Shen Colette, Lee Yueh, Kondziolka Douglas, Ibrahim Mohannad, Lian Jun, Jain Rajan, Zhu Tong, Comaniciu Dorin, Balter James M, Cao Yue

СтатьяМногоцентровое исследованиеПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

PURPOSE: The purpose of this study was to investigate an extended self-adapting nnU-Net framework for detecting and segmenting brain metastases (BM) on magnetic resonance imaging (MRI).

METHODS AND MATERIALS: Six different nnU-Net systems with adaptive data sampling, adaptive Dice loss, or different patch/batch sizes were trained and tested for detecting and segmenting intraparenchymal BM with a size ≥2 mm on 3 Dimensional (3D) post-Gd T1-weighted MRI volumes using 2092 patients from 7 institutions (1712, 195, and 185 patients for training, validation, and testing, respectively). Gross tumor volumes of BM delineated by physicians for stereotactic radiosurgery were collected retrospectively and curated at each institute. Additional centralized data curation was carried out to create gross tumor volumes of uncontoured BM by 2 radiologists to improve the accuracy of ground truth. The training data set was augmented with synthetic BMs of 1025 MRI volumes using a 3D generative pipeline. BM detection was evaluated by lesion-level sensitivity and false-positive (FP) rate. BM segmentation was assessed by lesion-level Dice similarity coefficient, 95-percentile Hausdorff distance, and average Hausdorff distance (HD). The performances were assessed across different BM sizes. Additional testing was performed using a second data set of 206 patients.

RESULTS

Of the 6 nnU-Net systems, the nnU-Net with adaptive Dice loss achieved the best detection and segmentation performance on the first testing data set. At an FP rate of 0.65 ± 1.17, overall sensitivity was 0.904 for all sizes of BM, 0.966 for BM ≥0.1 cm3, and 0.824 for BM <0.1 cm3. Mean values of Dice similarity coefficient, 95-percentile Hausdorff distance, and average HD of all detected BMs were 0.758, 1.45, and 0.23 mm, respectively. Performances on the second testing data set achieved a sensitivity of 0.907 at an FP rate of 0.57 ± 0.85 for all BM sizes, and an average HD of 0.33 mm for all detected BM.

CONCLUSIONS

Our proposed extension of the self-configuring nnU-Net framework substantially improved small BM detection sensitivity while maintaining a controlled FP rate. Clinical utility of the extended nnU-Net model for assisting early BM detection and stereotactic radiosurgery planning will be investigated.

Для цитирования: Yoo Youngjin, Gibson Eli, Zhao Gengyan, Re Thomas J, Parmar Hemant, Das Jyotipriya, Wang Hesheng, Kim Michelle M, Shen Colette, Lee Yueh, Kondziolka Douglas, Ibrahim Mohannad, Lian Jun, Jain Rajan, Zhu Tong, Comaniciu Dorin, Balter James M, Cao Yue. Extended nnU-Net for Brain Metastasis Detection and Segmentation in Contrast-Enhanced Magnetic Resonance Imaging With a Large Multi-Institutional Data Set.. International journal of radiation oncology, biology, physics. 2024. DOI: 10.1016/j.ijrobp.2024.07.2318.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.