MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1088/1361-6560/ad64b9

Медицинская библиотека · Physics in medicine and biology · 2024

Resolution limits for radiation-induced acoustic imaging forin vivoradiation dosimetry.

Kumar Pandey Prabodh, Bjegovic Kristina, Gonzalez Gilberto, Wang Xinxin, Liu An, Chen Yong, Xiang Liangzhong

СтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

Objective.Radiation-induced acoustic (RA) computed tomographic (RACT) imaging is being thoroughly explored for radiation dosimetry. It is essential to understand how key machine parameters like beam pulse, size, and energy deposition affect image quality in RACT. We investigate the intricate interplay of these parameters and how these factors influence dose map resolution in RACT.Approach.We first conduct an analytical assessment of time-domain RA signals and their corresponding frequency spectra for certain testcases, and computationally validate these analyses. Subsequently, we simulated a series of x-ray-based RACT (XACT) experiments and compared the simulations with experimental measurements.In-silicoreconstruction studies have also been conducted to demonstrate the resolution limits imposed by the temporal pulse profiles on RACT. XACT experiments were performed using clinical machines and the reconstructions were analyzed for resolution capabilities.Main results.Our paper establishes the theory for predicting the time- and frequency-domain behavior of RA signals. We illustrate that the frequency content of RA signal is not solely dependent on the spatial energy deposition characteristics but also on the temporal features of radiation. The same spatial energy deposition through a Gaussian pulse and a rectangular pulse of equal pulsewidths results in different frequency spectra of the RA signals. RA signals corresponding to the rectangular pulse exhibit more high-frequency content than their Gaussian pulse counterparts and hence provide better resolution in the reconstructions. XACT experiments with ∼3.2 us and ∼4 us rectangular radiation pulses were performed, and the reconstruction results were found to correlate well with thein-silicoresults.Significance.Here, we discuss the inherent resolution limits for RACT-based radiation dosimetric systems. While our study is relevant to the broader community engaged in research on photoacoustics, x-ray-acoustics, and proto/ionoacoustics, it holds particular significance for medical physics researchers aiming to set up RACT for dosimetry and radiography using clinical radiation machines.

Для цитирования: Kumar Pandey Prabodh, Bjegovic Kristina, Gonzalez Gilberto, Wang Xinxin, Liu An, Chen Yong, Xiang Liangzhong. Resolution limits for radiation-induced acoustic imaging forin vivoradiation dosimetry.. Physics in medicine and biology. 2024. DOI: 10.1088/1361-6560/ad64b9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.