MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0241722

Медицинская библиотека · PloS one · 2020

Validity of bioelectrical impedance to estimate fat-free mass in boys with Duchenne muscular dystrophy.

Grilo Evellyn C, Cunha Thais A, Costa Ádila Danielly S, Araújo Bárbara G M, Lopes Márcia Marília G D, Maciel Bruna L L, Alves Camila X, Vermeulen-Serpa Karina M, Dourado-Júnior Mário Emílio T, Leite-Lais Lucia, Brandão-Neto José, Vale Sancha Helena L

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The evaluation of fat-free mass (FFM) in patients with Duchenne muscular dystrophy (DMD) is useful to investigate disease progression and therapeutic efficacy. This study aimed to validate the Bioelectrical impedance (BIA) method compared with the dual-energy X-ray absorptiometry (DXA) for estimating the %FFM in boys with DMD. This is a cross-sectional study performed with children and adolescents diagnosed with DMD. Resistance and reactance were measured with a BIA analyzer, from which eight predictive equations estimated the %FFM. The %FFM was also determined by DXA and its used as a reference method. Pearson correlation test, coefficient of determination, the root-mean-square error, the interclass correlation coefficient, and linear regression analysis were performed between %FFM values obtained by BIA and DXA. The agreement between these values was verified with the Bland-Altman plot analysis. Forty-six boys aged from 5 to 20 years were enrolled in the study. All the equations showed a correlation between the %FFM estimated by BIA and determined by DXA (p < 0.05). The Bland-Altman method indicated that two equations have a significant bias (p < 0.05) and six equations showed no significant bias of %FFM (p > 0.05). However, one of them has high variation and wide limits of agreement. Five of eight %FFM predictive equations tested in DMD were accurate when compared with the DXA. It can be concluded that BIA is a validity method to evaluate patients with DMD.

Для цитирования: Grilo Evellyn C, Cunha Thais A, Costa Ádila Danielly S, Araújo Bárbara G M, Lopes Márcia Marília G D, Maciel Bruna L L, Alves Camila X, Vermeulen-Serpa Karina M, Dourado-Júnior Mário Emílio T, Leite-Lais Lucia, Brandão-Neto José, Vale Sancha Helena L. Validity of bioelectrical impedance to estimate fat-free mass in boys with Duchenne muscular dystrophy.. PloS one. 2020. DOI: 10.1371/journal.pone.0241722.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.