MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/opx.0000000000000018

Медицинская библиотека · Optometry and vision science : official publication of the American Academy of Optometry · 2013

Medical applications and outcomes of bitangential scleral lenses.

Visser Esther-Simone, Van der Linden Bart J J J, Otten Henny M, Van der Lelij Allegonda, Visser Rients

СтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate the clinical results of a new scleral lens design with a bitangential (nonrotationally symmetrical) periphery.

METHODS

All the necessary data were obtained during the 1-year study period. The bitangential scleral lenses were fitted and monitored according to a standardized fitting methodology. They were cut by precise submicron lathing from high-oxygen-permeable materials (including 10 scleral lenses from Menicon Z material). Subjective performance, visual acuity, and scleral lens-fitting characteristics were recorded after a median of 9.4 weeks (range, 3 weeks to 1 year).

RESULTS

Diagnoses in the 213 eyes (in 144 patients) were keratoconus (n = 121 eyes; 56.8%), ocular surface diseases (n = 31 eyes; 14.6%), penetrating keratoplasty (n = 29 eyes; 13.6%), and other forms of irregular astigmatism (n = 28 eyes; 13.1%). Many patients (164 lenses; 77.0%) gave high ratings for comfort. The most common diameter was 20.0 mm (162 lenses; 76.1%) (range, 18.5 to 21.5 mm). Median decimal best-corrected visual acuity with the bitangential scleral lenses was 0.8 (equivalent to Snellen 20/25) (range, 0 to 1.5). Most bitangential scleral lenses showed good fitting characteristics: optimal values were seen for lens movement (208 lenses; 97.7%) and lens position (208 lenses; 97.7%). Median central corneal clearance was 0.2 mm; clearances differed in the four peripheral directions. The median stabilization axis was 140 degrees (range, 0 to 180 degrees) in the right eyes and 60 degrees (range, 0 to 180 degrees) in the left eyes.

CONCLUSIONS

The bitangential scleral lens-fitting and performance characteristics were clear and effective for the health professional and the patient. The high-oxygen-permeable material Menicon Z may, in theory, be of benefit to corneas with a high oxygen demand.

Для цитирования: Visser Esther-Simone, Van der Linden Bart J J J, Otten Henny M, Van der Lelij Allegonda, Visser Rients. Medical applications and outcomes of bitangential scleral lenses.. Optometry and vision science : official publication of the American Academy of Optometry. 2013. DOI: 10.1097/opx.0000000000000018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.