MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000097866

Медицинская библиотека · Nephron. Clinical practice · 2006

Enhanced flow velocity after stenting of renal arteries is associated with decreased renal function.

Girndt Matthias, Kaul Harald, Maute Carla, Kramann Bernhard, Köhler Hans, Uder Michael

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Atherosclerotic renal artery stenosis (RAS) is frequently treated by angioplasty and stent placement. Duplex sonography is an established noninvasive technique for patient follow-up. There is lack of evidence that routine monitoring of asymptomatic patients with stable blood pressure is needed.

METHODS

Renal duplex sonography was performed in 64 patients who had received percutaneous angioplasty and stenting of an atherosclerotic RAS. Duplex sonographic diagnosis was made by a combination of direct flow measurement in the renal artery and evaluation of intrarenal resistive indices. Renal function was determined by serum creatinine and calculated glomerular filtration rate (GFR).

RESULTS

With a mean follow-up of 28 months after angioplasty, a flow velocity of >2.0 m/s was detected within the stented arteries in 11/64 patients. While the initial blood pressure and GFR as well as the influence of angioplasty on these parameters were not different, the decrease in renal function over time was significantly higher in patients with flow enhancement (annual GFR decrease, 8.0 ml/min vs. 0.8 ml/min; p < 0.05).

CONCLUSION

Follow-up duplex sonography in patients after renal artery stenting detected an unexpectedly high rate of in-stent restenosis associated with enhanced loss of renal function. Routine duplex sonographic follow-up may detect patients at risk of more rapidly declining renal function.

Для цитирования: Girndt Matthias, Kaul Harald, Maute Carla, Kramann Bernhard, Köhler Hans, Uder Michael. Enhanced flow velocity after stenting of renal arteries is associated with decreased renal function.. Nephron. Clinical practice. 2006. DOI: 10.1159/000097866.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.