Journal of inherited metabolic disease · 2026
Real-Life Application of a Point-of-Care Biosensor for Phenylalanine in Patients With Phenylketonuria.
СтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Gondrand Corentin, Reischl-Hajiabadi Anna T, Bonedeau Estelle, Weiß Nicolas, Schneider Gerd, Fahn Maurice, Myers Frederic, Städle Philipp Minel, Jeltsch Kathrin, Hoffmann Georg F, Okun Jürgen G, Haas Dorothea, Garbade Sven F, Johnsson Kai, Opladen Thomas
Аннотация
Phenylketonuria (PKU) is a rare metabolic disorder causing elevated phenylalanine (PHE) levels requiring lifelong dietary or pharmacological management and regular monitoring. Current PHE monitoring methods, such as tandem mass spectrometry (FIA-MS/MS), are laboratory and sample transport-dependent, leading to delays in obtaining results. This highlights the need for accessible point-of-care (PoC) solutions. Building on a previously developed bioluminescence-based PHE quantification method, we created a PoC PHE sensor integrated with a smartphone app (phenyx app) for real-time monitoring and data sharing. In a clinical study with PKU patients, we evaluated the reliability of the sensor and the app by comparing at-home PHE measurements with dried blood samples (DBS) analyzed using the gold standard FIA-MS/MS. We also assessed time differences between sampling and results, sensor practicality, and user experience. Forty-seven PKU patients (median age 10.0 years, range 0.7-53.4) performed one supervised and four at-home measurements using the PHE sensor, alongside DBS sampling for FIA-MS/MS. The sensor showed higher PHE values than FIA-MS/MS, with a mean difference of 84.8 μmol/L (p = 0.0017). Variability was influenced by test supervision (clinic vs. home) and test kit age (greater difference in older batches, p = 0.001). Usability of the PHE sensor and phenyx app was rated favorably; all patients preferred the PHE sensor over laboratory testing. PoC measurement using the PHE sensor and phenyx app is feasible, reliable, and provides rapid results comparable to FIA-MS/MS, representing a key step toward patient self-testing. Trial Registration: NCT05998109, NCT06940193, DRKS00031972.